Fuel Cell Polarisation Curve: Cell Voltage, Power and Efficiency

Cell voltage at a current density from the activation, ohmic and mass-transport losses, with power density, stack voltage, current, power and efficiency.

Thermal power plantChemical and fertiliser

Inputs

Examples: Illustrative 600 mA/cm2, 100 cells of 200 cm2Part load 200 mA/cm2High-temperature cell 400 mA/cm2: low A, 0.5 Ohm cm2

Accepted: 1 to 3,000 mA/cm²
Accepted: 0.5 to 1.3 V
Accepted: 0 to 100 Ω·cm²
Accepted: 0 to 0.2 V
Accepted: 0 to 0.01 V
Accepted: 0 to 0.05
Accepted: 1 to 2,000
Accepted: 1 to 10,000 cm²
Accepted: 50 to 100 %

Results

V = E_oc − ir − A ln i − m e^(ni) with i in mA/cm² inside the logarithm and exponential; E_oc includes the exchange-current term. Efficiency η = μ_f V/1.481 V (HHV) or V/1.253 V (LHV).

Cell voltage0.67341V
Power density404.04mW/cm²
Ohmic loss120.00mV
Activation loss A ln i223.89mV
Mass-transport loss2.7005mV
Stack voltage67.341V
Stack current120.00A
Stack power8.0809kW
Efficiency on the higher heating value43.195%
Efficiency on the lower heating value51.052%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 600 mA/cm2, 100 cells of 200 cm2. The inputs, in the units selected above:

InputValue
Current density600.00 mA/cm²
Practical open-circuit constant1.0200 V
Area-specific resistance0.20000 Ω·cm²
Tafel slope constant0.035000 V
Mass-transport constant3.0000e-05 V
Mass-transport exponent (cm² per mA)0.007500 -
Cells in the stack100.00 -
Active area per cell200.00 cm²
Fuel utilisation95.000 %

Applying the formula below gives:

ResultValue
Cell voltage0.67341 V
Power density404.04 mW/cm²
Ohmic loss120.00 mV
Activation loss A ln i223.89 mV
Mass-transport loss2.7005 mV
Stack voltage67.341 V
Stack current120.00 A
Stack power8.0809 kW
Efficiency on the higher heating value43.195 %
Efficiency on the lower heating value51.052 %

Open this example in the calculator and change any input.

Formula

\(V = E_{oc} - ir - A\ln i - me^{ni}, \quad \eta_{HHV} = \mu_f\frac{V}{1.481}\)

Variables

Symbol Meaning SI unit
\(i\) Current density A/m²
\(E_{oc}\) Practical open-circuit constant V
\(r\) Area-specific resistance Ω·m²
\(A\) Tafel slope constant V
\(m\) Mass-transport constant V
\(n\) Mass-transport exponent (cm² per mA) -
\(N\) Cells in the stack -
\(A_c\) Active area per cell m²
\(\mu_f\) Fuel utilisation -
\(V_c\) Cell voltage V
\(P/A\) Power density W/m²
\(\Delta V_{ohm}\) Ohmic loss V
\(\Delta V_{act}\) Activation loss A ln i V
\(\Delta V_{trans}\) Mass-transport loss V
\(V_{stack}\) Stack voltage V
\(I\) Stack current A
\(P\) Stack power W
\(\eta_{HHV}\) Efficiency on the higher heating value -
\(\eta_{LHV}\) Efficiency on the lower heating value -

Method and standards

Empirical polarisation model.

Where it is used

  • Fuel cell stack sizing and operating point selection.
  • Fitting test data and comparing cells.

Common mistakes

  • Using A/m² inside the logarithm (the constants are for mA/cm²).
  • Quoting efficiency without saying HHV or LHV.

Assumptions and limits

  • Steady state; constants from a fit to the cell in question.

References

  • Empirical polarisation equation V = E_oc − ir − A ln i − m exp(ni)

Questions and answers

Where do the losses come from?

Activation (slow electrode reactions) dominates at low current, resistance in the middle and mass transport (gas supply, water flooding) near the limiting current.

What efficiency does a PEM stack reach?

At 0.65–0.70 V per cell, about 44–47 % on the higher heating value or 52–56 % on the lower; it rises at part load as voltage increases.

What do the defaults represent?

Illustrative PEM constants (E_oc 1.02 V, 0.2 Ω·cm², A 0.035 V, m 3 × 10⁻⁵ V, n 0.0075 cm²/mA) at 600 mA/cm² for 100 cells of 200 cm².

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.