FireCADCalc

Landfill Gas Generation by First-Order Decay

Methane and landfill gas generated in a year from a landfill taking constant waste for some years, by first-order decay (LandGEM form), with energy.

Sugar mill and cogenerationDistillery and ethanolPulp and paper

Inputs

Examples: 50,000 t/yr for 20 years, year 25Wet site k 0.15, 10 years, year 8

Results

Q = kL₀M e^(−k(t − τ)) integrated over the years of acceptance (the continuous form of US EPA LandGEM). Default k = 0.05/yr and L₀ = 100 m³/t follow LandGEM's conventional values; wet tropical sites decay faster (k up to 0.2). Only 50–85 % of gas is usually collected.

Methane generation510.19m³/h
Landfill gas generation927.62m³/h
Methane energy (LHV 35.8 MJ/m³)5.0736MW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50,000 t/yr for 20 years, year 25. The inputs, in the units selected above:

InputValue
Waste accepted per year (t)50,000 -
Years of acceptance20.000 -
Year of interest (from opening)25.000 -
Decay rate (per year)0.050000 -
Methane potential (m³/t)100.00 -
Methane fraction of landfill gas50.000 %

Applying the formula below gives:

ResultValue
Methane generation280.80 m³/h
Landfill gas generation561.60 m³/h
Methane energy (LHV 35.8 MJ/m³)2.7924 MW

Open this example in the calculator and change any input.

Formula

\(Q_{CH_4}(t) = L_0M\left[e^{-k(t - n)} - e^{-kt}\right]\ (t > n), \quad L_0M(1 - e^{-kt})\ (t \le n)\)

Variables

Symbol Meaning SI unit
\(M\) Waste accepted per year (t) -
\(n\) Years of acceptance -
\(t\) Year of interest (from opening) -
\(k\) Decay rate (per year) -
\(L_0\) Methane potential (m³/t) -
\(f_{CH_4}\) Methane fraction of landfill gas -
\(Q_{CH_4}\) Methane generation m³/s
\(Q_{LFG}\) Landfill gas generation m³/s
\(P\) Methane energy (LHV 35.8 MJ/m³) W

Method and standards

First-order decay.

Where it is used

  • Landfill gas engine sizing.
  • Methane emission estimates.

Common mistakes

  • Expecting all gas to be collected.
  • Using dry-site k for wet climates.

Assumptions and limits

  • Constant acceptance; single decay rate. The continuous form differs slightly from LandGEM's 0.1-year discrete summation; M and n are used as entered (n may be fractional).
  • L₀ and the methane flow are taken at the reference state of the 35.8 MJ/m³ heating value (0 °C, 1 atm); if L₀ is quoted at LandGEM's 25 °C reference, the energy here is about 9 % high.

References

  • First-order decay Q = kL₀M e^(−kt)
  • US EPA LandGEM user's manual (2005)

Questions and answers

Why does generation peak at closure?

Fresh waste keeps adding gas while earlier waste decays; once acceptance stops, generation falls exponentially.

What does k depend on?

Moisture and temperature: dry sites about 0.02 per year, wet or tropical sites 0.1–0.2.

What do the defaults represent?

50,000 t a year for 20 years, five years after closure.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.