Worked example
Example: 1 MWh, one cycle a day. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Battery capacity (kWh) | 1,000.0 - |
| Usable depth of discharge | 90.000 % |
| Round-trip efficiency | 88.000 % |
| Cycles per day | 1.0000 - |
| Operating days per year | 300.00 - |
| Peak tariff per kWh | 11.000 - |
| Off-peak tariff per kWh | 6.0000 - |
| Installed cost per kWh of capacity | 18,000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Energy delivered per cycle (kWh) | 792.00 |
| Saving per cycle | 3,312.0 |
| Saving per year | 993,600 |
| Simple payback (years) | 18.116 |
Open this example in the calculator and change any input.
Formula
\(S_d = E_b\,DoD(\eta_{rt}c_p - c_o)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(E_b\) | Battery capacity (kWh) | - |
| \(DoD\) | Usable depth of discharge | - |
| \(\eta_{rt}\) | Round-trip efficiency | - |
| \(n_c\) | Cycles per day | - |
| \(N_d\) | Operating days per year | - |
| \(c_p\) | Peak tariff per kWh | - |
| \(c_o\) | Off-peak tariff per kWh | - |
| \(C\) | Installed cost per kWh of capacity | - |
| \(E_d\) | Energy delivered per cycle (kWh) | - |
| \(S_d\) | Saving per cycle | - |
| \(S_y\) | Saving per year | - |
| \(t_{pb}\) | Simple payback (years) | - |
Method and standards
Energy balance.
Where it is used
- Industrial and commercial battery projects.
- Tariff studies.
Common mistakes
- Ignoring round-trip losses.
- Ignoring degradation.
Assumptions and limits
- One full cycle a day by default.
- Simple payback only: no discounting, degradation, replacement or auxiliary (cooling, inverter standby) consumption. With no saving the payback is never, and none is shown.
References
- Saving per cycle = E_b DoD (η c_p − c_o)
Questions and answers
1 MWh, 90 % DoD, 88 % round trip, 11 vs 6 per kWh, 300 days?
About 3,312 a cycle, 993,600 a year.
Demand charges?
Peak shaving may save more than energy arbitrage; add it separately.
Break-even tariff gap?
The peak price must exceed the off-peak price divided by the round-trip efficiency.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.