FireCADCalc

Battery Storage: Peak/Off-Peak Arbitrage Saving

Daily and annual saving of a battery charged off-peak and discharged at peak, from capacity, depth of discharge, round-trip efficiency, cycles and the two tariffs.

Inputs

Examples: 1 MWh, one cycle a dayTwo cycles a day

Results

Ignores degradation and replacement; cycle life limits the years of service.

Energy delivered per cycle (kWh)792.00
Saving per cycle3,312.0
Saving per year993,600
Simple payback (years)18.116

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1 MWh, one cycle a day. The inputs, in the units selected above:

InputValue
Battery capacity (kWh)1,000.0 -
Usable depth of discharge90.000 %
Round-trip efficiency88.000 %
Cycles per day1.0000 -
Operating days per year300.00 -
Peak tariff per kWh11.000 -
Off-peak tariff per kWh6.0000 -
Installed cost per kWh of capacity18,000 -

Applying the formula below gives:

ResultValue
Energy delivered per cycle (kWh)792.00
Saving per cycle3,312.0
Saving per year993,600
Simple payback (years)18.116

Open this example in the calculator and change any input.

Formula

\(S_d = E_b\,DoD(\eta_{rt}c_p - c_o)\)

Variables

Symbol Meaning SI unit
\(E_b\) Battery capacity (kWh) -
\(DoD\) Usable depth of discharge -
\(\eta_{rt}\) Round-trip efficiency -
\(n_c\) Cycles per day -
\(N_d\) Operating days per year -
\(c_p\) Peak tariff per kWh -
\(c_o\) Off-peak tariff per kWh -
\(C\) Installed cost per kWh of capacity -
\(E_d\) Energy delivered per cycle (kWh) -
\(S_d\) Saving per cycle -
\(S_y\) Saving per year -
\(t_{pb}\) Simple payback (years) -

Method and standards

Energy balance.

Where it is used

  • Industrial and commercial battery projects.
  • Tariff studies.

Common mistakes

  • Ignoring round-trip losses.
  • Ignoring degradation.

Assumptions and limits

  • One full cycle a day by default.
  • Simple payback only: no discounting, degradation, replacement or auxiliary (cooling, inverter standby) consumption. With no saving the payback is never, and none is shown.

References

  • Saving per cycle = E_b DoD (η c_p − c_o)

Questions and answers

1 MWh, 90 % DoD, 88 % round trip, 11 vs 6 per kWh, 300 days?

About 3,312 a cycle, 993,600 a year.

Demand charges?

Peak shaving may save more than energy arbitrage; add it separately.

Break-even tariff gap?

The peak price must exceed the off-peak price divided by the round-trip efficiency.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.