Flue Gas Concentration: Wet ↔ Dry Basis

Convert a flue gas concentration or composition between wet and dry basis from the moisture content, and the dry flow from the wet flow.

Thermal power plantSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Wet to dry, 12 % moistureDry to wet, 18 % moisture

Volume (mole) fraction in the wet gas. From a dry-basis ratio x_d use x_d/(1 + x_d); from a mass fraction convert with the molar masses (18 for water, about 30 for flue gas).

Results

Mass emission is the same on either basis: C_d × dry flow = C_w × wet flow.

Dry-basis concentration204.55mg/Nm³
Wet-basis concentration180.00mg/Nm³
Dry flue gas flow132,000Nm³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Wet to dry, 12 % moisture. The inputs, in the units selected above:

InputValue
Concentration given onWet basis (convert to dry)
Concentration180.00 mg/Nm³
Water vapour volume fraction (of the wet gas)12.000 %
Wet flue gas flow (normal)150,000 Nm³/h

Applying the formula below gives:

ResultValue
Dry-basis concentration204.55 mg/Nm³
Wet-basis concentration180.00 mg/Nm³
Dry flue gas flow132,000 Nm³/h

Open this example in the calculator and change any input.

Formula

\(C_d = \frac{C_w}{1 - x_{H_2O}}, \quad \dot V_d = \dot V_w(1 - x_{H_2O})\)

Variables

Symbol Meaning SI unit
\(\text{given}\) Concentration given on -
\(C\) Concentration kg/m³
\(x_{H_2O}\) Water vapour volume fraction -
\(\dot V_w\) Wet flue gas flow (normal) Nm³/s
\(C_d\) Dry-basis concentration kg/m³
\(C_w\) Wet-basis concentration kg/m³
\(\dot V_d\) Dry flue gas flow Nm³/s

Method and standards

Mole balance.

Where it is used

  • CEMS data checks.
  • Emission reporting.

Common mistakes

  • Correcting O₂ before moisture.
  • Mass fraction for volume fraction of water.

Assumptions and limits

  • The moisture is the volume (mole) fraction of water vapour in the wet gas. Moisture given as a mass fraction or on a dry basis must be converted first (dry-basis ratio x_d → x_d/(1 + x_d)).

  • Ideal gas.

References

  • Dilution by water vapour: C_dry = C_wet/(1 − x_H₂O)

Questions and answers

180 mg/Nm³ wet with 12 % moisture?

204.5 mg/Nm³ dry.

Why do limits use dry gas?

Moisture varies with fuel and firing; a dry basis compares plants fairly.

O₂ correction?

Apply it after converting to the dry basis.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators