Worked example
Example: Wet to dry, 12 % moisture. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Concentration given on | Wet basis (convert to dry) |
| Concentration | 180.00 mg/Nm³ |
| Water vapour volume fraction (of the wet gas) | 12.000 % |
| Wet flue gas flow (normal) | 150,000 Nm³/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Dry-basis concentration | 204.55 mg/Nm³ |
| Wet-basis concentration | 180.00 mg/Nm³ |
| Dry flue gas flow | 132,000 Nm³/h |
Open this example in the calculator and change any input.
Formula
\(C_d = \frac{C_w}{1 - x_{H_2O}}, \quad \dot V_d = \dot V_w(1 - x_{H_2O})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{given}\) | Concentration given on | - |
| \(C\) | Concentration | kg/m³ |
| \(x_{H_2O}\) | Water vapour volume fraction | - |
| \(\dot V_w\) | Wet flue gas flow (normal) | Nm³/s |
| \(C_d\) | Dry-basis concentration | kg/m³ |
| \(C_w\) | Wet-basis concentration | kg/m³ |
| \(\dot V_d\) | Dry flue gas flow | Nm³/s |
Method and standards
Mole balance.
Where it is used
- CEMS data checks.
- Emission reporting.
Common mistakes
- Correcting O₂ before moisture.
- Mass fraction for volume fraction of water.
Assumptions and limits
The moisture is the volume (mole) fraction of water vapour in the wet gas. Moisture given as a mass fraction or on a dry basis must be converted first (dry-basis ratio x_d → x_d/(1 + x_d)).
Ideal gas.
References
- Dilution by water vapour: C_dry = C_wet/(1 − x_H₂O)
Questions and answers
180 mg/Nm³ wet with 12 % moisture?
204.5 mg/Nm³ dry.
Why do limits use dry gas?
Moisture varies with fuel and firing; a dry basis compares plants fairly.
O₂ correction?
Apply it after converting to the dry basis.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.