FireCADCalc

Venturi Scrubber Efficiency and Pressure Drop (Calvert)

Particle collection efficiency of a venturi scrubber by Calvert's equation from throat velocity, liquid-to-gas ratio and factor f, with pressure drop.

Thermal power plantSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 100 m/s, 1 L/m3, 1 um60 m/s, 1.5 L/m3, 2 um, hot gas

Results

Calvert's equations in their CGS form (ΔP in cm H₂O, d_p in µm, μ in poise); the calculator converts. Efficiency for a size distribution needs the grade efficiency integrated over it.

Cunningham correction1.1034
Pressure drop5.4545kPa
Penetration4.2180e-04%
Collection efficiency100.000%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 m/s, 1 L/m3, 1 um. The inputs, in the units selected above:

InputValue
Throat gas velocity100.00 m/s
Liquid-to-gas ratio1.0000 L/m³
Particle diameter1.0000 µm
Particle density2,000.0 kg/m³
Liquid density1,000.0 kg/m³
Gas viscosity0.018500 cP
Calvert empirical factor (0.25 hydrophobic, 0.5 hydrophilic)0.25000 -
Gas temperature25.000 °C

Applying the formula below gives:

ResultValue
Cunningham correction1.1852
Pressure drop10.101 kPa
Penetration6.5900 %
Collection efficiency93.410 %

Open this example in the calculator and change any input.

Formula

\(P_t = \exp\left[-\frac{6.1\times10^{-9}\rho_L\rho_pC_cd_p^2f^2\Delta P}{\mu_G^2}\right], \quad \Delta P = 1.03\times10^{-6}v_t^2\frac{Q_L}{Q_G}\ \ (\mathrm{CGS};\ Q_L/Q_G\ \mathrm{L/m^3})\)

\(C_c = 1 + \frac{6.21\times10^{-4}T}{d_p}\ \ (T\ \mathrm{K},\ d_p\ \mathrm{\mu m})\)

Variables

Symbol Meaning SI unit
\(v_t\) Throat gas velocity m/s
\(Q_L/Q_G\) Liquid-to-gas ratio (L/m³) -
\(d_p\) Particle diameter m
\(\rho_p\) Particle density kg/m³
\(\rho_L\) Liquid density kg/m³
\(\mu_G\) Gas viscosity Pa·s
\(f\) Calvert empirical factor (0.25 hydrophobic, 0.5 hydrophilic) -
\(T\) Gas temperature K
\(C_c\) Cunningham correction -
\(\Delta P\) Pressure drop Pa
\(P_t\) Penetration -
\(\eta\) Collection efficiency -

Method and standards

Calvert's venturi equations.

Where it is used

  • Boiler, incinerator and dryer dust scrubbers.
  • Fume and mist control.

Common mistakes

  • Applying one size's efficiency to the whole dust.
  • Ignoring the mist eliminator.

Assumptions and limits

  • Single particle size; Calvert's empirical f.

References

  • Calvert (1977)
  • Chem. Eng. 84(18): 54; Cooper and Alley
  • Air Pollution Control: A Design Approach
  • 4th ed. (Waveland, 2011)
  • ch. 9 (venturi scrubbers)

Questions and answers

Why does pressure drop matter so much?

Efficiency rises with the energy put into the throat; collecting submicron particles costs fan power.

What is the f factor?

An empirical factor for droplet–particle interaction: about 0.25 for hydrophobic, up to 0.5 for hydrophilic dusts.

What do the defaults give?

100 m/s throat, 1 L/m³: about 10 kPa and 93 % on 1 µm particles of 2,000 kg/m³.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.