Worked example
Example: 100 m/s, 1 L/m3, 1 um. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Throat gas velocity | 100.00 m/s |
| Liquid-to-gas ratio | 1.0000 L/m³ |
| Particle diameter | 1.0000 µm |
| Particle density | 2,000.0 kg/m³ |
| Liquid density | 1,000.0 kg/m³ |
| Gas viscosity | 0.018500 cP |
| Calvert empirical factor (0.25 hydrophobic, 0.5 hydrophilic) | 0.25000 - |
| Gas temperature | 25.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Cunningham correction | 1.1852 |
| Pressure drop | 10.101 kPa |
| Penetration | 6.5900 % |
| Collection efficiency | 93.410 % |
Open this example in the calculator and change any input.
Formula
\(P_t = \exp\left[-\frac{6.1\times10^{-9}\rho_L\rho_pC_cd_p^2f^2\Delta P}{\mu_G^2}\right], \quad \Delta P = 1.03\times10^{-6}v_t^2\frac{Q_L}{Q_G}\ \ (\mathrm{CGS};\ Q_L/Q_G\ \mathrm{L/m^3})\)
\(C_c = 1 + \frac{6.21\times10^{-4}T}{d_p}\ \ (T\ \mathrm{K},\ d_p\ \mathrm{\mu m})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(v_t\) | Throat gas velocity | m/s |
| \(Q_L/Q_G\) | Liquid-to-gas ratio (L/m³) | - |
| \(d_p\) | Particle diameter | m |
| \(\rho_p\) | Particle density | kg/m³ |
| \(\rho_L\) | Liquid density | kg/m³ |
| \(\mu_G\) | Gas viscosity | Pa·s |
| \(f\) | Calvert empirical factor (0.25 hydrophobic, 0.5 hydrophilic) | - |
| \(T\) | Gas temperature | K |
| \(C_c\) | Cunningham correction | - |
| \(\Delta P\) | Pressure drop | Pa |
| \(P_t\) | Penetration | - |
| \(\eta\) | Collection efficiency | - |
Method and standards
Calvert's venturi equations.
Where it is used
- Boiler, incinerator and dryer dust scrubbers.
- Fume and mist control.
Common mistakes
- Applying one size's efficiency to the whole dust.
- Ignoring the mist eliminator.
Assumptions and limits
- Single particle size; Calvert's empirical f.
References
- Calvert (1977)
- Chem. Eng. 84(18): 54; Cooper and Alley
- Air Pollution Control: A Design Approach
- 4th ed. (Waveland, 2011)
- ch. 9 (venturi scrubbers)
Questions and answers
Why does pressure drop matter so much?
Efficiency rises with the energy put into the throat; collecting submicron particles costs fan power.
What is the f factor?
An empirical factor for droplet–particle interaction: about 0.25 for hydrophobic, up to 0.5 for hydrophilic dusts.
What do the defaults give?
100 m/s throat, 1 L/m³: about 10 kPa and 93 % on 1 µm particles of 2,000 kg/m³.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.