FireCADCalc

Gaussian Plume: Ground-Level Centreline Concentration

Ground-level centreline concentration downwind of a stack from emission rate, wind speed, effective height and the dispersion coefficients there.

Thermal power plantSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 100 kg/h SO2 from a 150 m effective stackLow stack, light wind

From Pasquill–Gifford curves for the stability class and distance.

Results

Includes full ground reflection; a screening estimate, not a regulatory model.

Ground-level centreline concentration201,946µg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 kg/h SO2 from a 150 m effective stack. The inputs, in the units selected above:

InputValue
Emission rate100,000 kg/h
Wind speed at stack height5.0000 m/s
Effective stack height (stack plus plume rise)150.00 m
Horizontal dispersion coefficient at the distance160.00 m
Vertical dispersion coefficient at the distance90.000 m

Applying the formula below gives:

ResultValue
Ground-level centreline concentration30,622 µg/m³

Open this example in the calculator and change any input.

Formula

\(C = \frac{Q}{\pi u \sigma_y \sigma_z}\exp\left(-\frac{H^2}{2\sigma_z^2}\right)\)

Variables

Symbol Meaning SI unit
\(Q\) Emission rate kg/s
\(u\) Wind speed at stack height m/s
\(H\) Effective stack height (stack plus plume rise) m
\(\sigma_y\) Horizontal dispersion coefficient at the distance m
\(\sigma_z\) Vertical dispersion coefficient at the distance m
\(C\) Ground-level centreline concentration kg/m³

Method and standards

Gaussian plume, ground-level centreline.

Where it is used

  • Stack height screening.
  • Emission impact estimates.

Common mistakes

  • Physical instead of effective height.
  • Wind speed at ground level.

Assumptions and limits

  • Steady, flat terrain, full ground reflection.
  • No reflection from the top of the mixing layer and no averaging-time correction (the σ curves are for about 10-minute averages): a screening estimate.

References

  • Gaussian plume with total ground reflection C = Q/(πuσ_yσ_z) exp(−H²/2σ_z²) (Turner, Workbook of Atmospheric Dispersion Estimates)

Questions and answers

100 kg/h SO₂, 5 m/s, H 150 m, σ_y 160, σ_z 90?

About 30622 µg/m³ on the centreline at that distance.

Why does a taller stack help?

Concentration falls with exp(−H²/2σ_z²).

Where do σ values come from?

Pasquill–Gifford curves for the stability class.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.