Worked example
Example: Illustrative: 60 W, 20 ms, 380 V bus down to 300 V, 90 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Load power | 60.000 W |
| Hold-up time | 20.000 ms |
| Capacitor voltage at the start | 380.00 V |
| Minimum voltage the converter accepts | 300.00 V |
| Converter efficiency | 90.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Required capacitance | 49.020 µF |
| Energy delivered by the capacitor | 1.3333 J |
| Fraction of the stored energy used | 37.673 % |
Open this example in the calculator and change any input.
Formula
\(C = \frac{2Pt_h}{\eta(V_1^2 - V_2^2)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Load power | W |
| \(t_h\) | Hold-up time | s |
| \(V_1\) | Capacitor voltage at the start | V |
| \(V_2\) | Minimum voltage the converter accepts | V |
| \(\eta\) | Converter efficiency | - |
| \(C\) | Required capacitance | F |
| \(\Delta E\) | Energy delivered by the capacitor | J |
| \(1 - (V_2/V_1)^2\) | Fraction of the stored energy used | - |
Method and standards
Energy balance of a discharging capacitor.
Where it is used
- Offline power supplies and LED drivers.
- Ride-through for controllers, memories and data loggers.
Common mistakes
- Using V₁²/2 without subtracting the minimum voltage.
- Ignoring capacitor tolerance and ageing.
Assumptions and limits
- Constant-power load, ideal capacitor.
References
- Capacitor energy balance for hold-up
Questions and answers
Why does the minimum voltage matter so much?
The usable energy is ½C(V₁² − V₂²); letting the converter run down to a lower voltage releases much more of the stored energy.
What hold-up time is typical?
Mains-powered IT supplies often specify 10–20 ms, one full mains cycle, to ride through brief dips and transfer switching.
What do the defaults represent?
An illustrative 60 W supply with a 380 V PFC bus that must ride through 20 ms down to 300 V at 90 % efficiency.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Erickson and Maksimović, Fundamentals of Power Electronics, 2nd ed. (Kluwer, 2001), ch. 18