FireCADCalc

Crystal Oscillator Load Capacitors and Frequency Pulling

Load capacitors for a Pierce crystal oscillator from the specified load capacitance and the strays, with the frequency error of other values.

Inputs

Examples: Illustrative: 12 pF crystal, 3 pF strays, two 18 pF capacitors32.768 kHz watch crystal 12.5 pF with 22 pF capacitors (runs slow)20 pF crystal, 4 pF strays, ideal values

Accepted: 1 to 100 pF
Accepted: 0 to 20 pF
Accepted: 0 to 1,000 pF
Accepted: 0 to 1,000 pF
Accepted: 0.1 to 20 pF
Accepted: 0.0001 to 0.1 pF

Results

C_L = C₁C₂/(C₁ + C₂) + C_stray; pulling Δf/f = (C_m/2)[1/(C₀ + C_L,actual) − 1/(C₀ + C_L)]. Too little load capacitance makes the oscillator run fast; too much, slow, and may weaken start-up.

Ideal equal load capacitors 2(C_L − C_stray)32.000pF
Load capacitance with the chosen capacitors20.000pF
Frequency error with the chosen capacitors (ppm)0
Pulling sensitivity at C_L (ppm/pF)-12.000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 12 pF crystal, 3 pF strays, two 18 pF capacitors. The inputs, in the units selected above:

InputValue
Specified load capacitance of the crystal12.000 pF
Stray capacitance (pins and PCB, 2–5 pF)3.0000 pF
Chosen capacitor C₁ (0 to use the ideal value)18.000 pF
Chosen capacitor C₂18.000 pF
Crystal shunt capacitance3.0000 pF
Crystal motional capacitance0.005000 pF

Applying the formula below gives:

ResultValue
Ideal equal load capacitors 2(C_L − C_stray)18.000 pF
Load capacitance with the chosen capacitors12.000 pF
Frequency error with the chosen capacitors (ppm)0
Pulling sensitivity at C_L (ppm/pF)-11.111

Open this example in the calculator and change any input.

Formula

\(C_1 = C_2 = 2(C_L - C_{stray}), \quad C_{L,actual} = \frac{C_1C_2}{C_1 + C_2} + C_{stray}, \quad \frac{\Delta f}{f} = \frac{C_m}{2}\left[\frac{1}{C_0 + C_{L,actual}} - \frac{1}{C_0 + C_L}\right]\)

Variables

Symbol Meaning SI unit
\(C_L\) Specified load capacitance of the crystal F
\(C_{stray}\) Stray capacitance (pins and PCB, 2–5 pF) F
\(C_1\) Chosen capacitor C₁ (0 to use the ideal value) F
\(C_2\) Chosen capacitor C₂ F
\(C_0\) Crystal shunt capacitance F
\(C_m\) Crystal motional capacitance F
\(C_{1} = C_{2}\) Ideal equal load capacitors 2(C_L − C_stray) F
\(C_{L,actual}\) Load capacitance with the chosen capacitors F
\(\Delta f/f\) Frequency error with the chosen capacitors (ppm) -
\(S\) Pulling sensitivity at C_L (ppm/pF) -

Method and standards

Crystal load capacitance and pulling.

Where it is used

  • Microcontroller and RTC clock circuits.
  • Radio reference oscillators and timing.

Common mistakes

  • Using C_L itself as each capacitor.
  • Forgetting the PCB and pin capacitance.

Assumptions and limits

  • Fundamental-mode Pierce oscillator; small pulling.

References

  • Pierce oscillator load capacitance and crystal pulling

Questions and answers

Why are the capacitors twice the load capacitance?

C₁ and C₂ appear in series across the crystal, so two equal capacitors give half their value, plus the strays.

How accurate must they be?

Typical pulling is 10–20 ppm per pF; with 5 % capacitors the error is usually a few ppm, smaller than the crystal's own tolerance.

What do the defaults represent?

An illustrative 12 pF crystal (C₀ 3 pF, C_m 5 fF) with 3 pF of strays, built with two 18 pF capacitors.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Horowitz and Hill, The Art of Electronics, 3rd ed. (Cambridge University Press, 2015), ch. 7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.