Worked example
Example: RC 10 kΩ, 100 µF, 12 V, after 1 s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Circuit | RC (resistor and capacitor) |
| Resistance | 10.000 kΩ |
| Capacitance (RC) | 100.00 µF |
| Inductance (RL) | 500.00 mH |
| Step (supply) voltage | 12.000 V |
| Time after the step | 1.0000 s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Time constant | 1.0000 s |
| Time to about 99.3 % (five time constants) | 5.0000 s |
| Share of the final value reached at t | 63.212 % |
| Capacitor voltage at t (RC, charging) | 7.5854 V |
| Current at t | 4.4146e-04 A |
| Cut-off frequency 1/(2πτ) | 0.15915 Hz |
| Energy stored when fully charged | 0.007200 J |
Open this example in the calculator and change any input.
Formula
\(\tau = R C \quad \text{or} \quad \tau = L / R\)
\(1 - e^{-t/\tau}, \quad v_C = V \left(1 - e^{-t/\tau}\right)\)
\(i(t) = \frac{V}{R} e^{-t/\tau}\ (\text{RC}), \quad i(t) = \frac{V}{R}\left(1 - e^{-t/\tau}\right)\ (\text{RL})\)
\(f_c = \frac{1}{2\pi\tau}, \quad W = \tfrac12 C V^2\ \text{or}\ \tfrac12 L I^2\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{circuit}\) | Circuit | - |
| \(R\) | Resistance | Ω |
| \(C\) | Capacitance (RC) | F |
| \(L\) | Inductance (RL) | H |
| \(V\) | Step (supply) voltage | V |
| \(t\) | Time after the step | s |
| \(\tau\) | Time constant | s |
| \(5\tau\) | Time to about 99.3 % (five time constants) | s |
| \(1 - e^{-t/\tau}\) | Share of the final value reached at t | - |
| \(v_C\) | Capacitor voltage at t (RC, charging) | V |
| \(i(t)\) | Current at t | A |
| \(f_c\) | Cut-off frequency 1/(2πτ) | 1/s |
| \(W\) | Energy stored when fully charged | J |
| \(I\) | Final current V/R (RL) | A |
Method and standards
A first-order circuit driven by a voltage step approaches its final value exponentially with time constant τ. The cut-off frequency of the same circuit used as a filter is 1/(2πτ).
Where it is used
- Timing circuits, signal filters and snubbers.
- Discharge time of capacitors for safety.
- Contactor coil and relay pick-up times.
Common mistakes
- Using diameter-style units (µF entered as F).
- Forgetting the source resistance in series.
- Assuming the capacitor is empty at the start.
Assumptions and limits
- Ideal components; step input; starts from zero.
References
- First-order circuit response (exponential charging)
Questions and answers
How long does a 10 kΩ, 100 µF circuit take to charge?
τ = RC = 1 s. After 1 s it reaches 63.2 % (7.6 V of 12 V) and after 5 s about 99.3 %.
What is the cut-off frequency?
1/(2πτ): 0.16 Hz for τ = 1 s. Above it an RC low-pass filter attenuates by 20 dB per decade.
How does an RL circuit differ?
τ = L/R and it is the current that rises: a 0.5 H, 100 Ω coil on 24 V reaches 33 % of its 0.24 A after 2 ms.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.