Coupled Inductors: Mutual Inductance, Series and Parallel Equivalents

Mutual inductance from coupling coefficient, the equivalent of two coupled inductors in series aiding or opposing and in parallel, and stored energy at a current.

Thermal power plantProcess steam and utilities

Inputs

Examples: Illustrative 10 and 4 mH, k = 0.6Loose air-core couplingTightly coupled transformer windings

Accepted: 1E-6 to 100,000 mH
Accepted: 1E-6 to 100,000 mH
Accepted: 0 to 1
Accepted: 0 to 100,000 A

Results

M = k√(L₁L₂); series L₁ + L₂ ± 2M; parallel (aiding) (L₁L₂ − M²)/(L₁ + L₂ − 2M). Measuring series aiding and opposing inductances gives M = (L₊ − L₋)/4, a common way to find coupling. With k = 1 and equal coils the parallel-aiding value equals each coil's inductance.

Mutual inductance245.00mH
Series aiding1,115.0mH
Series opposing135.00mH
Parallel aiding18.333mH
Energy stored, series aiding0.55750J

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 10 and 4 mH, k = 0.6. The inputs, in the units selected above:

InputValue
Inductance 110.000 mH
Inductance 24.0000 mH
Coupling coefficient0.60000 -
Current (series connection)2.0000 A

Applying the formula below gives:

ResultValue
Mutual inductance3.7947 mH
Series aiding21.589 mH
Series opposing6.4105 mH
Parallel aiding3.9934 mH
Energy stored, series aiding0.043179 J

Open this example in the calculator and change any input.

Formula

\(M = k\sqrt{L_1L_2}, \quad L_{s\pm} = L_1 + L_2 \pm 2M, \quad L_{p+} = \frac{L_1L_2 - M^2}{L_1 + L_2 - 2M}\)

Variables

Symbol Meaning SI unit
\(L_1\) Inductance 1 H
\(L_2\) Inductance 2 H
\(k\) Coupling coefficient -
\(I\) Current (series connection) A
\(M\) Mutual inductance H
\(L_{s+}\) Series aiding H
\(L_{s-}\) Series opposing H
\(L_{p+}\) Parallel aiding H
\(W\) Energy stored, series aiding J

Method and standards

Coupled inductors.

Where it is used

  • Inductor and transformer design checks.
  • Teaching and lab measurements.

Common mistakes

  • Forgetting the dot convention (aiding versus opposing).
  • Using k above 1.

Assumptions and limits

  • Linear inductors; no losses.

References

  • Coupled inductor relations

Questions and answers

How is mutual inductance measured?

Measure the series inductance both ways round: M is a quarter of the difference.

What coupling do transformers have?

Close to 1 for iron-cored power transformers; air-cored coils are often 0.1–0.5.

What do the defaults represent?

Illustrative 10 mH and 4 mH coils with coupling 0.6 carrying 2 A in series.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Hayt, Kemmerly and Durbin, Engineering Circuit Analysis, 8th ed. (McGraw-Hill, 2012)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.