FireCADCalc

Equal-Tangent Vertical Curve Through a Fixed Point

Length of an equal-tangent vertical curve that passes through a given elevation at a given station (a clearance point), with its BVC and EVC elevations.

Inputs

Examples: Illustrative sag through a clearance pointCrest over a culvert before the PVIPoint at the PVI station

Accepted: 0 to 1,000,000 m
Accepted: -500 to 9,000 m
Accepted: -20 to 20 %
Accepted: -20 to 20 %
Accepted: 0 to 1,000,000 m
Accepted: -500 to 9,000 m

Results

On an equal-tangent curve the elevation at a point a distance d from the PVI (negative before it) is E_PVI + g₁d + (g₂ − g₁)(d + L/2)²/2L. Setting it equal to the required elevation gives a quadratic in L: L²/4 + (d − 2Q)L + d² = 0 with Q = (E_P − E_PVI − g₁d)/(g₂ − g₁); the longer root keeps the point within the curve. Used to clear a culvert, match a crossroad or give clearance under a bridge.

Curve length100.00m
BVC station450.00m
BVC elevation31.000m
EVC elevation31.000m
Rate of change of grade (per 100 m)4.0000%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative sag through a clearance point. The inputs, in the units selected above:

InputValue
Station of the PVI2,000.0 m
Elevation of the PVI85.000 m
Incoming grade-4.0000 %
Outgoing grade3.0000 %
Station of the fixed point2,030.0 m
Required elevation at the fixed point86.200 m

Applying the formula below gives:

ResultValue
Curve length125.63 m
BVC station1,937.2 m
BVC elevation87.513 m
EVC elevation86.884 m
Rate of change of grade (per 100 m)5.5719 %

Open this example in the calculator and change any input.

Formula

\(E_P = E_{PVI} + g_1d + \frac{(g_2 - g_1)(d + L/2)^2}{2L} \ \Rightarrow\ \frac{L^2}4 + (d - 2Q)L + d^2 = 0\)

Variables

Symbol Meaning SI unit
\(Sta_{PVI}\) Station of the PVI m
\(E_{PVI}\) Elevation of the PVI m
\(g_1\) Incoming grade -
\(g_2\) Outgoing grade -
\(Sta_P\) Station of the fixed point m
\(E_P\) Required elevation at the fixed point m
\(L\) Curve length m
\(Sta_{BVC}\) BVC station m
\(E_{BVC}\) BVC elevation m
\(E_{EVC}\) EVC elevation m
\(r\) Rate of change of grade (per 100 m) -

Method and standards

Curve through a point.

Where it is used

  • Road profiles with fixed control levels.
  • Clearance and cover checks.

Common mistakes

  • Taking the short root.
  • Point outside the curve.

Assumptions and limits

  • Equal tangents; parabolic curve.

References

  • Equal-tangent vertical curve through a fixed point

Questions and answers

Why are there two possible lengths?

The quadratic has two roots; only the one that keeps the fixed point between BVC and EVC is usable.

When is this used?

To make a profile pass over a culvert, under a bridge or meet a fixed road level.

What do the defaults represent?

An illustrative sag curve from −4 % to +3 % at a PVI of station 2,000 m, 85.00 m, required to pass through 86.20 m at station 2,030 m.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ghilani and Wolf, Elementary Surveying: An Introduction to Geomatics, 13th ed. (Pearson, 2012)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.