Worked example
Example: Illustrative 1,500 m at 30 C, 950 hPa. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Measured distance (at reference index) | 1,500.0 m |
| Carrier wavelength | 658.00 nm |
| Air temperature | 30.000 °C |
| Air pressure | 950.00 hPa |
| Relative humidity | 60.000 % |
| Instrument reference temperature | 12.000 °C |
| Instrument reference pressure | 1,013.2 hPa |
| Instrument reference humidity | 60.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Group refractivity (ppm) | 299.26 |
| Air refractivity at field conditions (ppm) | 251.87 |
| Refractivity at reference conditions (ppm) | 286.34 |
| Correction (ppm) | 34.460 |
| Corrected distance | 1,500.1 m |
Open this example in the calculator and change any input.
Formula
\(N_g = 287.6155 + \frac{4.88660}{\lambda^2} + \frac{0.06800}{\lambda^4}, \quad n_a = 1 + \left[\frac{273.15}{1013.25}\frac{N_gP}{T} - \frac{11.27e}{T}\right]10^{-6}, \quad D = D'\frac{n_{ref}}{n_a}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D'\) | Measured distance (at reference index) | m |
| \(\lambda\) | Carrier wavelength | m |
| \(t\) | Air temperature | K |
| \(P\) | Air pressure | Pa |
| \(RH\) | Relative humidity | - |
| \(t_{ref}\) | Instrument reference temperature | K |
| \(P_{ref}\) | Instrument reference pressure | Pa |
| \(RH_{ref}\) | Instrument reference humidity | - |
| \(N_g\) | Group refractivity (ppm) | - |
| \((n_a - 1)10^6\) | Air refractivity at field conditions (ppm) | - |
| \((n_{ref} - 1)10^6\) | Refractivity at reference conditions (ppm) | - |
| \(\Delta\) | Correction (ppm) | - |
| \(D\) | Corrected distance | m |
Method and standards
Atmospheric correction.
Where it is used
- Total station and EDM distance measurement.
- Setting the ppm value on an instrument.
Common mistakes
- Entering pressure in the wrong units.
- Applying the correction twice when the instrument already did.
Assumptions and limits
- Mean atmosphere along the line; light-wave EDM.
References
- Group refractive index and IUGG air refractivity
Questions and answers
How big is the atmospheric correction?
About 1 ppm per °C and per 3.6 hPa; at altitude in hot weather it can reach 40–60 ppm (6–9 mm per 150 m).
Does humidity matter?
Very little for light-wave EDMs (well under 1 ppm normally), unlike microwave instruments.
What do the defaults represent?
An illustrative 1,500 m line measured at 30 °C, 950 hPa and 60 % humidity with a 658 nm instrument referenced to 12 °C, 1013.25 hPa, 60 %.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ghilani and Wolf, Elementary Surveying: An Introduction to Geomatics, 13th ed. (Pearson, 2012), IUGG, Resolutions of the XXII General Assembly, Resolution 3: refractive index of air for EDM (1999)