FireCADCalc

Two-Peg Test: Level Collimation Error

True height difference, collimation error per unit distance and the corrected far-staff reading of a surveying level from the readings of a two-peg test.

Inputs

Examples: Illustrative: pegs 60 m apart, 1.524/1.187 midway, 1.402/1.071 near ALevel in adjustment: 1.385/0.902 and 1.250/0.767Large error: 2.010/1.455 and 1.890/1.320, 40 m

Accepted: 0 to 10 m
Accepted: 0 to 10 m
Accepted: 0 to 10 m
Accepted: 0 to 10 m
Accepted: 5 to 200 m
Accepted: 0 to 20 m

Results

Midway readings cancel the collimation error, giving the true difference. Near-A readings expose it: e is the error of the far reading over the peg distance (positive: the line of sight rises).

The error exceeds about 5 mm per 100 m (a common tolerance): adjust the level.

True difference (midway) a₁ − b₁337.00mm
Apparent difference near A a₂ − b₂331.00mm
Collimation error over the peg distance6.0000mm
Collimation error per 100 m10.000mm
Correct reading on B for the second set-up1.0650m
Line-of-sight inclination (+ up)20.626″

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: pegs 60 m apart, 1.524/1.187 midway, 1.402/1.071 near A. The inputs, in the units selected above:

InputValue
Staff reading on A, level midway1.5240 m
Staff reading on B, level midway1.1870 m
Staff reading on A, level near A1.4020 m
Staff reading on B, level near A1.0710 m
Distance between the pegs60.000 m
Distance from the level to A in the second set-up3.0000 m

Applying the formula below gives:

ResultValue
True difference (midway) a₁ − b₁337.00 mm
Apparent difference near A a₂ − b₂331.00 mm
Collimation error over the peg distance6.0000 mm
Collimation error per 100 m10.000 mm
Correct reading on B for the second set-up1.0650 m
Line-of-sight inclination (+ up)20.626 ″

Open this example in the calculator and change any input.

Formula

\(\Delta h = a_1 - b_1, \quad e = (a_1 - b_1) - (a_2 - b_2), \quad b_{2,correct} = a_2 - \Delta h\)

Variables

Symbol Meaning SI unit
\(a_1\) Staff reading on A, level midway m
\(b_1\) Staff reading on B, level midway m
\(a_2\) Staff reading on A, level near A m
\(b_2\) Staff reading on B, level near A m
\(L\) Distance between the pegs m
\(d_{near}\) Distance from the level to A in the second set-up m
\(\Delta h\) True difference (midway) a₁ − b₁ m
\(\Delta h_2\) Apparent difference near A a₂ − b₂ m
\(e\) Collimation error over the peg distance m
\(e/L\) Collimation error per 100 m m
\(b_{2,correct}\) Correct reading on B for the second set-up m
\(\alpha\) Line-of-sight inclination (+ up) rad

Method and standards

Level collimation testing.

Where it is used

  • Checking automatic and digital levels before use.
  • Quality records for precise levelling.

Common mistakes

  • Setting up the second station far from A.
  • Not repeating readings to average out reading errors.

Assumptions and limits

  • Curvature and refraction negligible over the peg distance.

References

  • Two-peg collimation test

Questions and answers

Why do midway readings give the true difference?

Equal sight lengths make the collimation error identical on both staffs, so it cancels in the difference.

How often should a level be tested?

Before a major job, after any knock and regularly (monthly) on site; keep backsight and foresight lengths equal to limit the effect.

What do the defaults represent?

An illustrative test with pegs 60 m apart: midway 1.524/1.187 m, then 3 m from A 1.402/1.071 m.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Uren and Price, Surveying for Engineers, 5th ed. (Palgrave Macmillan, 2010), ch. 3, Ghilani and Wolf, Elementary Surveying: An Introduction to Geomatics, 13th ed. (Pearson, 2012), ch. 5

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.