Worked example
Example: 30 m tape at 35 °C, 100 N, suspended, 1.5 m rise. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Measured length | 30.000 m |
| Field temperature | 35.000 °C |
| Standard temperature | 20.000 °C |
| Expansion coefficient | 11.600 µm/(m·K) |
| Applied pull | 0.10000 kN |
| Standard pull | 0.050000 kN |
| Tape cross-section | 3.0000 mm² |
| Tape modulus | 200.00 GPa |
| Tape weight per length | 0.25000 N/m |
| Height difference between ends | 1.5000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Temperature correction | 5.2200 mm |
| Pull correction | 2.5000 mm |
| Sag correction (suspended) | -7.0312 mm |
| Slope correction | -37.523 mm |
| Corrected horizontal length | 29.963 m |
Open this example in the calculator and change any input.
Formula
\(C_t = \alpha L(T - T_0), \quad C_p = \frac{(P - P_0)L}{AE}, \quad C_s = -\frac{w^2L^3}{24P^2}, \quad L_c = L + C_t + C_p + C_s, \quad C_h = -\left(L_c - \sqrt{L_c^2 - h^2}\right), \quad L_h = L_c + C_h\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L\) | Measured length | m |
| \(T\) | Field temperature | K |
| \(T_0\) | Standard temperature | K |
| \(\alpha\) | Expansion coefficient | 1/K |
| \(P\) | Applied pull | N |
| \(P_0\) | Standard pull | N |
| \(A\) | Tape cross-section | m² |
| \(E\) | Tape modulus | Pa |
| \(w\) | Tape weight per length | N/m |
| \(h\) | Height difference between ends | m |
| \(C_t\) | Temperature correction | m |
| \(C_p\) | Pull correction | m |
| \(C_s\) | Sag correction (suspended) | m |
| \(C_h\) | Slope correction | m |
| \(L_h\) | Corrected horizontal length | m |
| \(L_c\) | Length after temperature, pull and sag corrections | m |
Method and standards
Tape corrections.
Where it is used
- Plant setting-out and baselines.
- Exam problems.
Common mistakes
- Applying sag correction to a tape lying on the ground.
- Wrong sign for temperature.
Assumptions and limits
The slope correction is applied to the length already corrected for temperature, pull and sag (L_c), in the exact form; h must be less than L_c.
Single-span suspension; uniform tape.
References
- Standard tape corrections (Punmia, Surveying, vol. 1–2 (Laxmi), vol. 1, ch. 3)
Questions and answers
Which correction is largest?
Usually sag for suspended tapes and slope on steep ground; temperature matters on hot days with long lines.
What is normal tension?
The pull at which the pull correction cancels the sag correction.
What do the defaults represent?
A 30 m steel tape used at 35 °C with 100 N pull, suspended, with 1.5 m height difference.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.