FireCADCalc

Sight Distance on a Horizontal Curve (Middle Ordinate)

Clearance needed to an obstruction for a required sight distance on a horizontal curve, and the sight distance that a given clearance provides.

Inputs

Examples: Illustrative 300 m curve, 160 m SSDUrban 120 m curve, 85 m SSDPassing sight on 800 m curve

Accepted: 10 to 100,000 m
Accepted: 1 to 2,000 m
Accepted: 0 to 200 m

Results

When the sight distance S is shorter than the curve, the line of sight is a chord whose arc along the lane is S; its middle ordinate is M = R[1 − cos(S/2R)] (S/2R in radians). Inverting gives the sight distance a clearance allows: S = 2R·acos(1 − M/R). Required stopping or passing sight distances come from the design speed; when S exceeds the curve length the line of sight extends onto the tangents and this formula is conservative.

Clearance needed for S10.604m
Sight distance with the available clearance138.87m
Clearance margin-2.6036m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 300 m curve, 160 m SSD. The inputs, in the units selected above:

InputValue
Radius to the centre of the inside lane300.00 m
Required sight distance (along the lane)160.00 m
Available clearance to the obstruction8.0000 m

Applying the formula below gives:

ResultValue
Clearance needed for S10.604 m
Sight distance with the available clearance138.87 m
Clearance margin-2.6036 m

Open this example in the calculator and change any input.

Formula

\(M = R\left[1 - \cos\frac{S}{2R}\right], \quad S = 2R\cos^{-1}\left(1 - \frac MR\right)\)

Variables

Symbol Meaning SI unit
\(R\) Radius to the centre of the inside lane m
\(S\) Required sight distance (along the lane) m
\(M_{av}\) Available clearance to the obstruction m
\(M\) Clearance needed for S m
\(S_{av}\) Sight distance with the available clearance m
\(M_{av} - M\) Clearance margin m

Method and standards

Curve sight distance.

Where it is used

  • Highway curve clearance checks.
  • Setting back cut slopes and walls.

Common mistakes

  • Measuring R to the road centreline.
  • Using degrees in the cosine without conversion.

Assumptions and limits

  • Sight distance shorter than the curve; flat road (no vertical effect).

References

  • Middle ordinate of the sight line
  • AASHTO
  • A Policy on Geometric Design of Highways and Streets (method of the middle ordinate)

Questions and answers

What counts as an obstruction?

Cut slopes, walls, buildings, bridge piers or vegetation on the inside of the curve.

Why measure to the inside lane?

Its drivers have the shortest line of sight around the curve.

What do the defaults represent?

An illustrative 300 m radius curve needing 160 m stopping sight distance, with 8 m clear to a cut slope.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ghilani and Wolf, Elementary Surveying: An Introduction to Geomatics, 13th ed. (Pearson, 2012)

Related calculators