FireCADCalc

Bolted Connection: Bolt Value from Shear and Bearing

Shear capacity of a bolt over its shear planes, bearing capacity on the thinnest plate, the governing bolt value and the number of bolts for a load.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 300 kN with M20 single shearDouble shear M24, bearing governsSmall M16 cleat

Accepted: 0.1 to 100,000 kN
Accepted: 5 to 80 mm
Accepted: 1 to 5,000 mm²
Accepted: 1 to 4
Accepted: 10 to 1,000 MPa
Accepted: 2 to 100 mm
Accepted: 10 to 2,000 MPa

Results

V_s = n_p·A_s·τ_a; V_b = d·t·σ_b on the thinnest plate (or the sum of plates bearing in one direction); bolt value = min. Use the stress area where threads cross the shear plane and the shank area where they do not. Long joints, large gaps or packing need reduction factors from the user's code; edge distance limits bearing too.

Shear value per bolt15.700kN
Bearing value per bolt32.000kN
Bolt value15.700kN
Bolts required4.0000
Bolt group utilisation95.541%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 300 kN with M20 single shear. The inputs, in the units selected above:

InputValue
Connection load300.00 kN
Bolt diameter20.000 mm
Bolt area in the shear plane (stress or shank area)245.00 mm²
Shear planes per bolt1.0000 -
Allowable bolt shear stress160.00 MPa
Thinnest plate thickness in bearing10.000 mm
Allowable bearing stress300.00 MPa

Applying the formula below gives:

ResultValue
Shear value per bolt39.200 kN
Bearing value per bolt60.000 kN
Bolt value39.200 kN
Bolts required8.0000
Bolt group utilisation95.663 %

Open this example in the calculator and change any input.

Formula

\(V_s = n_pA_s\tau_a, \quad V_b = dt\sigma_b, \quad n = \left\lceil\frac{P}{\min(V_s, V_b)}\right\rceil\)

Variables

Symbol Meaning SI unit
\(P\) Connection load N
\(d\) Bolt diameter m
\(A_s\) Bolt area in the shear plane (stress or shank area) m²
\(n_p\) Shear planes per bolt -
\(\tau_a\) Allowable bolt shear stress Pa
\(t\) Thinnest plate thickness in bearing m
\(\sigma_b\) Allowable bearing stress Pa
\(V_s\) Shear value per bolt N
\(V_b\) Bearing value per bolt N
\(V\) Bolt value N
\(n\) Bolts required -
\(\eta\) Bolt group utilisation -

Method and standards

Bolt value.

Where it is used

  • Bracing, splice and cleat connections.
  • Checking existing bolted joints.

Common mistakes

  • Using shank area where threads are in the shear plane.
  • Ignoring bearing on thin plates.

Assumptions and limits

  • Concentric load shared equally; bearing-type joint.

References

  • Bearing-type bolted joint (working stress)

Questions and answers

What is the bolt value?

The smaller of a bolt's shear and bearing strength: the load one bolt can carry in that joint.

Double shear doubles the bolt value?

Shear capacity doubles; bearing usually then governs, set by the middle plate's thickness.

What do the defaults represent?

An illustrative 300 kN lap joint with M20 bolts (245 mm² stress area) in single shear at 160 MPa, 10 mm plates at 300 MPa bearing.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Subramanian, Design of Steel Structures (Oxford University Press, 2008), Salmon, Johnson and Malhas, Steel Structures: Design and Behavior, 5th ed. (Pearson, 2009)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.