FireCADCalc

Wind Velocity Pressure and Force on a Surface

Wind speed at a height by the power law, the velocity pressure ½ρV², and the force on a surface or member from its force coefficient and area.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 39 m/s at 10 m, 20 m height, open countryCoastal 50 m/s, stack top at 60 m

Use the averaging time your code and the exponent α are based on (hourly mean, 10-minute mean or 3-second gust): mixing them changes q by up to about 2 times.

Results

Power-law profile: α about 0.10 over sea, 0.14 open country, 0.22 suburbs, 0.33 city centres. Design to your building code's basic speed, terrain, topography and importance factors; this page shows the physics.

Wind speed at z42.974m/s
Velocity pressure1.1312kPa
Wind force29.410kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 39 m/s at 10 m, 20 m height, open country. The inputs, in the units selected above:

InputValue
Reference wind speed39.000 m/s
Reference height10.000 m
Height of interest20.000 m
Power-law exponent (terrain)0.14000 -
Air density1.2250 kg/m³
Force (shape) coefficient1.3000 -
Projected area20.000 m²

Applying the formula below gives:

ResultValue
Wind speed at z42.974 m/s
Velocity pressure1.1312 kPa
Wind force29.410 kN

Open this example in the calculator and change any input.

Formula

\(V_z = V_r\left(\frac{z}{z_r}\right)^\alpha, \quad q_z = \frac12\rho V_z^2, \quad F = C_fq_zA\)

Variables

Symbol Meaning SI unit
\(V_r\) Reference wind speed m/s
\(z_r\) Reference height m
\(z\) Height of interest m
\(\alpha\) Power-law exponent (terrain) -
\(\rho\) Air density kg/m³
\(C_f\) Force (shape) coefficient -
\(A\) Projected area m²
\(V_z\) Wind speed at z m/s
\(q_z\) Velocity pressure Pa
\(F\) Wind force N

Method and standards

Velocity pressure.

Where it is used

  • Wind on stacks, signboards and equipment.
  • Checking temporary structures.

Common mistakes

  • Using gust and mean speeds interchangeably.
  • Omitting code factors in design.

Assumptions and limits

  • The averaging time of V_r (hourly mean, 10-minute mean or 3-second gust) must match the profile exponent and the code's coefficients; the page does not know which one was entered.

  • Steady wind; neutral atmosphere.

References

  • Velocity pressure q = ½ρV² with the power-law wind profile (Simiu and Scanlan, Wind Effects on Structures)

Questions and answers

Why does wind speed grow with height?

Ground friction slows the wind near the surface; the boundary layer is hundreds of metres deep.

What is a force coefficient?

The ratio of wind force to velocity pressure times area: about 1.2–2 for flat plates and lattice members, 0.5–1.2 for cylinders.

What do the defaults represent?

A 39 m/s reference wind at 10 m, a surface at 20 m in open country, 20 m² with C_f = 1.3.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.