FireCADCalc

Triangular Truss Member Forces (Method of Joints)

Support reactions and member forces of a simple triangular truss (two rafters and a tie) carrying a vertical load at the apex, with the apex anywhere along the span.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 10 m symmetric truss, 2.5 m rise, 50 kNLean-to: apex 3 m from left, 8 m span

Results

Pin-jointed members, load at the apex only, one support on rollers. Flat trusses (small rise) give very large rafter and tie forces.

Left reaction25.000kN
Right reaction25.000kN
Left rafter force (compression)55.902kN
Right rafter force (compression)55.902kN
Tie force (tension)50.000kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 m symmetric truss, 2.5 m rise, 50 kN. The inputs, in the units selected above:

InputValue
Span10.000 m
Rise of the apex2.5000 m
Apex distance from the left support5.0000 m
Vertical load at the apex50.000 kN

Applying the formula below gives:

ResultValue
Left reaction25.000 kN
Right reaction25.000 kN
Left rafter force (compression)55.902 kN
Right rafter force (compression)55.902 kN
Tie force (tension)50.000 kN

Open this example in the calculator and change any input.

Formula

\(R_A = P\frac{L - a}{L}, \quad F_{AC} = \frac{R_A}{\sin\theta_1}, \quad T = F_{AC}\cos\theta_1, \quad \tan\theta_1 = \frac ha\)

Variables

Symbol Meaning SI unit
\(L\) Span m
\(h\) Rise of the apex m
\(a\) Apex distance from the left support m
\(P\) Vertical load at the apex N
\(R_A\) Left reaction N
\(R_B\) Right reaction N
\(F_{AC}\) Left rafter force (compression) N
\(F_{BC}\) Right rafter force (compression) N
\(T_{AB}\) Tie force (tension) N

Method and standards

Joint equilibrium.

Where it is used

  • Simple roof trusses and A-frames.
  • Teaching statics.

Common mistakes

  • Ignoring self weight at panel points.
  • Mixing up compression and tension members.

Assumptions and limits

  • Pin joints; load at apex.

References

  • Method of joints (Timoshenko and Young, Theory of Structures, 2nd ed. (McGraw-Hill))

Questions and answers

Why does the tie force rise for flat trusses?

Horizontal equilibrium at the support: tie force = reaction / tan(rafter angle), which grows as the angle falls.

Which members are in compression?

Under downward apex load, both rafters are in compression and the tie in tension.

What do the defaults represent?

A 10 m symmetric roof truss with a 2.5 m rise carrying 50 kN at the apex.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.