Worked example
Example: 1200 kN on 450 x 500. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Axial load (on the basis of your allowable stresses: service for allowable-stress design) | 1,200.0 kN |
| Plate width | 450.00 mm |
| Plate length | 500.00 mm |
| Largest projection beyond the column (cantilever) | 100.00 mm |
| Allowable bending stress of the plate | 185.00 MPa |
| Allowable bearing pressure on the concrete | 10.000 MPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Bearing pressure P/(BN) | 5.3333 MPa |
| Bearing utilisation | 53.333 % |
| Plate thickness c√(3q/f_b) | 29.409 mm |
Open this example in the calculator and change any input.
Formula
\(q = \frac{P}{BN}, \quad t = c\sqrt{\frac{3q}{f_b}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Axial load (on the basis of your allowable stresses: service for allowable-stress design) | N |
| \(B\) | Plate width | m |
| \(N\) | Plate length | m |
| \(c\) | Largest projection beyond the column (cantilever) | m |
| \(f_b\) | Allowable bending stress of the plate | Pa |
| \(f_c\) | Allowable bearing pressure on the concrete | Pa |
| \(q\) | Bearing pressure P/(BN) | Pa |
| \(q/f_c\) | Bearing utilisation | - |
| \(t\) | Plate thickness c√(3q/f_b) | m |
Method and standards
Cantilever plate strip.
Where it is used
- Column and equipment base plates.
- Pipe rack and platform columns.
Common mistakes
- Gross projection from the wrong face.
- Ignoring moments.
Assumptions and limits
- Concentric load, uniform pressure.
- Allowable-stress basis with the elastic section modulus t²/6; limit-state codes (IS 800, AISC LRFD) use factored loads and the plastic modulus t²/4, giving a thinner plate.
- A bearing utilisation above 1 is flagged.
References
- Elastic bending of a uniformly loaded cantilever strip (strength of materials)
Questions and answers
1200 kN on a 450 × 500 plate with 100 mm projection?
Bearing 5.33 MPa; thickness 29.4 mm.
Why three?
From M = qc²/2 and Z = t²/6: σ = 3qc²/t².
Moments on the column?
Then the pressure is not uniform; use an eccentric method.