Worked example
Example: Illustrative 120 kN on 6 x 5 m bay, tension only. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Horizontal force on the bay | 120.00 kN |
| Bay width | 6.0000 m |
| Bay height | 5.0000 m |
| Bracing action | Tension-only (one diagonal acts) |
| Diagonal cross-section area | 1,500.0 mm² |
| Minimum radius of gyration | 30.000 mm |
| Elastic modulus | 200.00 GPa |
| Effective length factor | 0.85000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Diagonal length | 7.8102 m |
| Diagonal force | 156.20 kN |
| Axial stress | 104.14 MPa |
| Slenderness ratio | 221.29 |
| Euler buckling load | 60.464 kN |
Open this example in the calculator and change any input.
Formula
\(L_d = \sqrt{b^2 + h^2}, \quad F = \frac{HL_d}{b}, \quad P_E = \frac{\pi^2EA}{(KL_d/r)^2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H\) | Horizontal force on the bay | N |
| \(b\) | Bay width | m |
| \(h\) | Bay height | m |
| \(\text{mode}\) | Bracing action | - |
| \(A\) | Diagonal cross-section area | m² |
| \(r\) | Minimum radius of gyration | m |
| \(E\) | Elastic modulus | Pa |
| \(K\) | Effective length factor | - |
| \(L_d\) | Diagonal length | m |
| \(F\) | Diagonal force | N |
| \(\sigma\) | Axial stress | Pa |
| \(KL/r\) | Slenderness ratio | - |
| \(P_E\) | Euler buckling load | N |
Method and standards
Bracing force.
Where it is used
- Wall and roof wind bracing.
- Crane and pipe rack longitudinal bracing.
Common mistakes
- Counting a slender compression diagonal.
- Forgetting the vertical force the bracing puts into columns.
Assumptions and limits
- Pin-jointed bay; single horizontal load; elastic buckling.
References
- Statics of a braced bay; Euler buckling
Questions and answers
Why design tension-only bracing?
Slender rods and flats buckle at tiny loads, so only the diagonal in tension is counted; the other goes slack.
What effective length for crossed diagonals?
Connected at the crossing, a compression diagonal often buckles over about half its length out of plane; the user's code sets K.
What do the defaults represent?
An illustrative 120 kN wind force on a 6 m wide by 5 m high bay with a 1,500 mm² angle (r 30 mm) in tension-only bracing.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Timoshenko and Gere, Theory of Elastic Stability, 2nd ed. (McGraw-Hill, 1961), Subramanian, Design of Steel Structures (Oxford University Press, 2008)