Worked example
Example: Illustrative 300/250 flange welded girder. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Top flange width | 300.00 mm |
| Top flange thickness | 20.000 mm |
| Web depth (clear) | 800.00 mm |
| Web thickness | 10.000 mm |
| Bottom flange width | 250.00 mm |
| Bottom flange thickness | 16.000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Area | 18,000 mm² |
| Centroid above bottom | 462.00 mm |
| Second moment of area, major axis | 206,332 cm⁴ |
| Elastic modulus to top fibre | 5,516.9 cm³ |
| Elastic modulus to bottom fibre | 4,466.1 cm³ |
| Plastic section modulus | 5,592.0 cm³ |
| Second moment of area, minor axis | 6,590.0 cm⁴ |
| Minor-axis radius of gyration | 60.507 mm |
Open this example in the calculator and change any input.
Formula
\(\bar y = \frac{\sum A_iy_i}{\sum A_i}, \quad I_x = \sum\left(I_i + A_i(y_i - \bar y)^2\right), \quad Z_p = \sum|A_i(y_i - y_p)|\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(b_1\) | Top flange width | m |
| \(t_1\) | Top flange thickness | m |
| \(h_w\) | Web depth (clear) | m |
| \(t_w\) | Web thickness | m |
| \(b_2\) | Bottom flange width | m |
| \(t_2\) | Bottom flange thickness | m |
| \(A\) | Area | m² |
| \(\bar y\) | Centroid above bottom | m |
| \(I_x\) | Second moment of area, major axis | m⁴ |
| \(Z_{top}\) | Elastic modulus to top fibre | m³ |
| \(Z_{bot}\) | Elastic modulus to bottom fibre | m³ |
| \(Z_p\) | Plastic section modulus | m³ |
| \(I_y\) | Second moment of area, minor axis | m⁴ |
| \(r_y\) | Minor-axis radius of gyration | m |
Method and standards
Built-up section.
Where it is used
- Plate girders and crane girders.
- Checking fabricated beams and columns.
Common mistakes
- Using the elastic centroid for plastic modulus.
- Forgetting the web's own I in the sum.
Assumptions and limits
- Plates only; welds and corner radii ignored.
References
- Elastic and plastic properties of plate sections
Questions and answers
Why is the plastic neutral axis not at the centroid?
In an unsymmetric section the line that halves the area differs from the one that balances first moments.
What is the shape factor?
Z_p divided by the smaller elastic modulus: about 1.1–1.2 for I-sections, showing the reserve beyond first yield.
What do the defaults represent?
An illustrative welded girder: 300 × 20 mm top flange, 800 × 10 mm web, 250 × 16 mm bottom flange.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Salmon, Johnson and Malhas, Steel Structures: Design and Behavior, 5th ed. (Pearson, 2009)