Worked example
Example: Illustrative: 400 mm I-beam, 180 x 13.5 flanges, 8.6 web, 6 m unbraced, UDL. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Overall depth | 400.00 mm |
| Flange width | 180.00 mm |
| Flange thickness | 13.500 mm |
| Web thickness | 8.6000 mm |
| Unbraced length | 6.0000 m |
| Moment gradient factor (1.0 uniform moment, 1.13 UDL, 1.35 central point load) | 1.1300 - |
| Elastic modulus | 200.00 GPa |
| Shear modulus | 77.000 GPa |
| Yield strength | 250.00 MPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Minor-axis second moment | 1,314.2 cm⁴ |
| Torsion constant | 37.433 cm⁴ |
| Warping constant | 490,048 cm⁶ |
| Elastic critical moment | 226.37 kN·m |
| First-yield moment f_y S_x | 273.46 kN·m |
| Plastic moment f_y Z_x | 309.58 kN·m |
| Slenderness √(M_p/M_cr) | 1.1694 |
Open this example in the calculator and change any input.
Formula
\(M_{cr} = C_1\frac{\pi}{L_b}\sqrt{EI_yGJ + \left(\frac{\pi E}{L_b}\right)^2 I_y C_w}\)
\(I_y = \frac{2t_f b_f^3}{12} + \frac{h_w t_w^3}{12}, \quad J = \frac{2b_f t_f^3 + h_w t_w^3}{3}, \quad C_w = \frac{I_{y,f}\,h_0^2}{4}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(h\) | Overall depth | m |
| \(b_f\) | Flange width | m |
| \(t_f\) | Flange thickness | m |
| \(t_w\) | Web thickness | m |
| \(L_b\) | Unbraced length | m |
| \(C_1\) | Moment gradient factor (1.0 uniform moment, 1.13 UDL, 1.35 central point load) | - |
| \(E\) | Elastic modulus | Pa |
| \(G\) | Shear modulus | Pa |
| \(f_y\) | Yield strength | Pa |
| \(I_y\) | Minor-axis second moment | m⁴ |
| \(J\) | Torsion constant | m⁴ |
| \(C_w\) | Warping constant | m⁶ |
| \(M_{cr}\) | Elastic critical moment | N·m |
| \(M_y\) | First-yield moment f_y S_x | N·m |
| \(M_p\) | Plastic moment f_y Z_x | N·m |
| \(\bar\lambda_{LT}\) | Slenderness √(M_p/M_cr) | - |
Method and standards
Elastic lateral-torsional buckling theory.
Where it is used
- Steel beams, crane girders and purlins with long unbraced lengths.
- Choosing the spacing of lateral restraints.
Common mistakes
- Taking the full span as unbraced when the compression flange is restrained.
- Ignoring a load applied above the shear centre, which lowers M_cr.
Assumptions and limits
- Doubly symmetric section, elastic, load at the shear centre, simple supports free to warp.
References
- Elastic lateral-torsional buckling of a doubly symmetric I-beam
Questions and answers
Why does an I-beam twist sideways?
The compression flange behaves like a column and tends to buckle sideways; because the tension flange resists, the section twists as it moves.
What does the factor C₁ do?
It raises M_cr for moment diagrams less severe than uniform moment: about 1.13 for a uniform load and 1.35 for a central point load on a simply supported span.
What do the defaults represent?
An illustrative 400 mm deep I-beam with 180 × 13.5 mm flanges and an 8.6 mm web, unbraced over 6 m under a uniform load.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Timoshenko and Gere, Theory of Elastic Stability, 2nd ed. (McGraw-Hill, 1961), sec. 6.2 and 6.3