Worked example
Example: Illustrative three spans 6-8-6 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Number of spans | Three spans |
| Span 1 length | 6.0000 m |
| Span 2 length | 8.0000 m |
| Span 3 length | 6.0000 m |
| Span 1 uniform load | 20.000 kN/m |
| Span 2 uniform load | 25.000 kN/m |
| Span 3 uniform load | 20.000 kN/m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Moment at support 1 (hogging negative) | -118.89 kN·m |
| Moment at support 2 (zero for two spans) | -118.89 kN·m |
| End reaction at support 0 | 40.185 kN |
| Reaction at support 1 | 179.81 kN |
| Reaction at support 2 | 179.81 kN |
| End reaction at support 3 (three spans) | 40.185 kN |
Open this example in the calculator and change any input.
Formula
\(M_{i-1}L_i + 2M_i(L_i + L_{i+1}) + M_{i+1}L_{i+1} = -\frac{w_iL_i^3 + w_{i+1}L_{i+1}^3}{4}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(n\) | Number of spans | - |
| \(L_1\) | Span 1 length | m |
| \(L_2\) | Span 2 length | m |
| \(L_3\) | Span 3 length | m |
| \(w_1\) | Span 1 uniform load | N/m |
| \(w_2\) | Span 2 uniform load | N/m |
| \(w_3\) | Span 3 uniform load | N/m |
| \(M_1\) | Moment at support 1 (hogging negative) | N·m |
| \(M_2\) | Moment at support 2 (zero for two spans) | N·m |
| \(R_0\) | End reaction at support 0 | N |
| \(R_1\) | Reaction at support 1 | N |
| \(R_2\) | Reaction at support 2 | N |
| \(R_3\) | End reaction at support 3 (three spans) | N |
Method and standards
Three-moment equation.
Where it is used
- Continuous floor beams, purlins and bridge decks.
- Checking computer analysis by hand.
Common mistakes
- Forgetting pattern loading for live load.
- Mixing sign conventions for moments.
Assumptions and limits
- Constant EI; unyielding supports; simple ends; uniform loads.
References
- Clapeyron's three-moment equation
Questions and answers
Why are the support moments negative?
Continuity causes hogging over interior supports; the sign convention takes sagging as positive.
Does it apply if EI varies between spans?
Not in this form: divide each span term by its own EI.
What do the defaults represent?
An illustrative three-span beam of 6, 8 and 6 m carrying 20, 25 and 20 kN/m.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Hibbeler, Structural Analysis, 10th ed. (Pearson, 2018)