Worked example
Example: Illustrative 300 kN with M20 single shear. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Connection load | 300.00 kN |
| Bolt diameter | 20.000 mm |
| Bolt area in the shear plane (stress or shank area) | 245.00 mm² |
| Shear planes per bolt | 1.0000 - |
| Allowable bolt shear stress | 160.00 MPa |
| Thinnest plate thickness in bearing | 10.000 mm |
| Allowable bearing stress | 300.00 MPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Shear value per bolt | 39.200 kN |
| Bearing value per bolt | 60.000 kN |
| Bolt value | 39.200 kN |
| Bolts required | 8.0000 |
| Bolt group utilisation | 95.663 % |
Open this example in the calculator and change any input.
Formula
\(V_s = n_pA_s\tau_a, \quad V_b = dt\sigma_b, \quad n = \left\lceil\frac{P}{\min(V_s, V_b)}\right\rceil\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Connection load | N |
| \(d\) | Bolt diameter | m |
| \(A_s\) | Bolt area in the shear plane (stress or shank area) | m² |
| \(n_p\) | Shear planes per bolt | - |
| \(\tau_a\) | Allowable bolt shear stress | Pa |
| \(t\) | Thinnest plate thickness in bearing | m |
| \(\sigma_b\) | Allowable bearing stress | Pa |
| \(V_s\) | Shear value per bolt | N |
| \(V_b\) | Bearing value per bolt | N |
| \(V\) | Bolt value | N |
| \(n\) | Bolts required | - |
| \(\eta\) | Bolt group utilisation | - |
Method and standards
Bolt value.
Where it is used
- Bracing, splice and cleat connections.
- Checking existing bolted joints.
Common mistakes
- Using shank area where threads are in the shear plane.
- Ignoring bearing on thin plates.
Assumptions and limits
- Concentric load shared equally; bearing-type joint.
References
- Bearing-type bolted joint (working stress)
Questions and answers
What is the bolt value?
The smaller of a bolt's shear and bearing strength: the load one bolt can carry in that joint.
Double shear doubles the bolt value?
Shear capacity doubles; bearing usually then governs, set by the middle plate's thickness.
What do the defaults represent?
An illustrative 300 kN lap joint with M20 bolts (245 mm² stress area) in single shear at 160 MPa, 10 mm plates at 300 MPa bearing.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Subramanian, Design of Steel Structures (Oxford University Press, 2008), Salmon, Johnson and Malhas, Steel Structures: Design and Behavior, 5th ed. (Pearson, 2009)