FireCADCalc

Stenter Drying: Water Evaporated and Heat

Water evaporated on a stenter from fabric speed, width, dry GSM and moisture in and out, the heat with a specific heat use per kg water, and fuel.

Food, dairy and textile

Inputs

Examples: 40 m/min, 1.8 m, 180 g/m2Heavy fabric 25 m/min

Fuel heat (on the LHV basis of the fuel value below) per kg of water evaporated.

Results

Better mangling (lower moisture in) saves far more than burner tuning; exhaust humidity control saves the rest.

Dry fabric720.00kg/h
Water evaporated446.40kg/h
Heat input620.00kW
Fuel48.522kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 40 m/min, 1.8 m, 180 g/m2. The inputs, in the units selected above:

InputValue
Fabric speed40.000 m/min
Fabric width1.8000 m
Dry fabric mass per m²180.00 g/m²
Moisture entering (kg water per kg dry fabric)0.65000 kg/kg
Moisture leaving0.070000 kg/kg
Heat per kg of water evaporated4.5000 MJ/kg
Fuel heating value46.000 MJ/kg

Applying the formula below gives:

ResultValue
Dry fabric777.60 kg/h
Water evaporated451.01 kg/h
Heat input563.76 kW
Fuel44.120 kg/h

Open this example in the calculator and change any input.

Formula

\(\dot m_{dry} = vWG, \quad \dot E = \dot m_{dry}(X_1 - X_2), \quad Q = \dot E q, \quad \dot m_f = \frac{Q}{LHV}\)

Variables

Symbol Meaning SI unit
\(v\) Fabric speed m/s
\(W\) Fabric width m
\(G\) Dry fabric mass per m² kg/m²
\(X_1\) Moisture entering (kg water per kg dry fabric) kg/kg
\(X_2\) Moisture leaving kg/kg
\(q\) Heat per kg of water evaporated J/kg
\(LHV\) Fuel heating value J/kg
\(\dot m_{dry}\) Dry fabric kg/s
\(\dot E\) Water evaporated kg/s
\(Q\) Heat input W
\(\dot m_f\) Fuel kg/s

Method and standards

Water balance with specific heat use.

Where it is used

  • Stenter energy audits.

Common mistakes

  • Using wet-basis moisture.
  • Using finished GSM including moisture.

Assumptions and limits

  • Steady running.
  • The heat use per kg of water is on the same (LHV) basis as the fuel heating value.

References

  • Definitions and mass and energy balances

Questions and answers

What heat per kg water is typical?

4–6 MJ/kg for direct-fired stenters.

Why dry basis moisture?

Pick-up after the mangle is quoted per kg of dry fabric (60–80 % for cotton).

Where does the heat go?

Evaporation, exhaust air and fabric heating; exhaust is the largest loss.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.