Worked example
Example: 10 t paddy, hot soak 70 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Paddy batch | 10,000 kg |
| Soak water to paddy ratio | 1.2000 kg/kg |
| Fresh water temperature | 25.000 °C |
| Soaking temperature | 70.000 °C |
| Paddy specific heat | 1.8000 kJ/(kg·K) |
| Steaming steam per kg paddy | 0.12000 kg/kg |
| Steam pressure (absolute) | 4.0000 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Soak water | 12,000 kg |
| Heat to the soak water and paddy | 3.0709 GJ |
| Steam to heat the soak | 1,439.5 kg |
| Steam for steaming | 1,200.0 kg |
| Total steam | 2,639.5 kg |
Open this example in the calculator and change any input.
Formula
\(M_w = r_wM, \quad Q_s = (M_wc_w + Mc_p)(T_s - T_1), \quad m_s = \frac{Q_s}{h_{fg}} + m_{st}M\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(M\) | Paddy batch | kg |
| \(r_w\) | Soak water to paddy ratio | kg/kg |
| \(T_1\) | Fresh water temperature | K |
| \(T_s\) | Soaking temperature | K |
| \(c_p\) | Paddy specific heat | J/(kg·K) |
| \(m_{st}\) | Steaming steam per kg paddy | kg/kg |
| \(p_s\) | Steam pressure (absolute) | Pa |
| \(M_w\) | Soak water | kg |
| \(Q_s\) | Heat to the soak water and paddy | J |
| \(m_1\) | Steam to heat the soak | kg |
| \(m_2\) | Steam for steaming | kg |
| \(m_s\) | Total steam | kg |
| \(c_w\) | Water specific heat, 4 186.8 | J/(kg·K) |
| \(h_{fg}\) | Latent heat of the steam at p_s (IF97) | J/kg |
Method and standards
Sensible heat with IF97 latent heat.
Where it is used
- Parboiling plant design.
Common mistakes
- Ignoring steam for steaming.
- Counting drain water as recovered.
Assumptions and limits
- No soak losses.
- The soak is heated indirectly: steam gives its latent heat h_fg and leaves as saturated condensate. If steam is sparged directly into the soak, the condensate also cools to the soak temperature and the steam needed is lower (about 13 % less at 4 bar and 70 °C).
- Water specific heat c_w = 4 186.8 J/(kg·K).
References
- Definitions and mass and energy balances
- Steam latent heat from IAPWS-IF97
Questions and answers
Why parboil?
Gelatinising the starch hardens the kernel, raising head rice yield and nutrition.
How much steam?
Typically 0.1–0.2 t of steam per tonne of paddy plus soak heating.
What does the husk supply?
Husk-fired boilers usually cover all parboiling and drying heat.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.