Oil Deodoriser: Stripping Steam and Heating

Stripping steam and heating duty of an edible oil deodoriser from oil flow, steam on oil, oil temperatures and specific heat, with oil–oil heat recovery.

Food, dairy and textile

Inputs

Examples: 300 t/d at 240 °C, 1 % steamPhysical refining 260 °C, 2 %

Results

The final heating to 230–260 °C is done with high-pressure steam or thermic fluid; vacuum of 2–4 mbar keeps stripping steam low.

Stripping steam166.67kg/h
Heat to reach deodorising temperature865.74kW
Net heating after recovery216.44kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 300 t/d at 240 °C, 1 % steam. The inputs, in the units selected above:

InputValue
Oil flow300.00 t/d
Stripping steam on oil1.0000 %
Oil specific heat2.2000 kJ/(kg·K)
Oil in80.000 °C
Deodorising temperature240.00 °C
Heat recovered by oil–oil exchange60.000 %

Applying the formula below gives:

ResultValue
Stripping steam125.00 kg/h
Heat to reach deodorising temperature1,222.2 kW
Net heating after recovery488.89 kW

Open this example in the calculator and change any input.

Formula

\(\dot m_s = s\dot M, \quad Q = \dot Mc_p(T_2 - T_1), \quad Q_n = Q(1 - \eta_r)\)

Variables

Symbol Meaning SI unit
\(\dot M\) Oil flow kg/s
\(s\) Stripping steam on oil -
\(c_p\) Oil specific heat J/(kg·K)
\(T_1\) Oil in K
\(T_2\) Deodorising temperature K
\(\eta_r\) Heat recovered by oil–oil exchange -
\(\dot m_s\) Stripping steam kg/s
\(Q\) Heat to reach deodorising temperature W
\(Q_n\) Net heating after recovery W

Method and standards

Sensible heat and steam rate.

Where it is used

  • Refinery utility sizing.

Common mistakes

  • Ignoring vacuum ejector steam (often larger than stripping steam).

Assumptions and limits

  • No losses.
  • Only the stripping steam is counted. Motive steam for the vacuum ejectors, often larger than the stripping steam, and heat losses are not included.

References

  • Definitions and mass and energy balances

Questions and answers

How much stripping steam?

0.5–1.5 % of oil for deodorising; 1–3 % for physical refining of high-FFA oils.

Why such high temperature?

Odour compounds and FFA must be volatile enough to strip under vacuum.

Why recover heat?

Hot deodorised oil can preheat the incoming oil, saving 50–80 % of the heating.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.