FireCADCalc

Electrostatic Charge Relaxation Time of a Liquid

Time constant for charge on a liquid to decay (τ = ε_r ε₀/κ) from its relative permittivity and conductivity, and the time for the charge to fall to a set fraction.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Hydrocarbon 1 pS/m, to 1 %Antistatic fuel 100 pS/m, to 1/e

Results

Low-conductivity liquids (below about 50 pS/m) hold charge for seconds: limit filling velocities and allow relaxation time before gauging. Screening estimate only, not a safety study or a basis for protective design.

Relaxation time constant17.708s
Time to fall to the fraction81.550s
1 = low-conductivity (≤ 50 pS/m) accumulator1.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hydrocarbon 1 pS/m, to 1 %. The inputs, in the units selected above:

InputValue
Relative permittivity2.0000 -
Electrical conductivity (pS/m)1.0000 -
Fraction of charge remaining1.0000 %

Applying the formula below gives:

ResultValue
Relaxation time constant17.708 s
Time to fall to the fraction81.550 s
1 = low-conductivity (≤ 50 pS/m) accumulator1.0000

Open this example in the calculator and change any input.

Formula

\(\tau = \frac{\varepsilon_r\varepsilon_0}{\kappa}, \quad t_f = \tau\ln\frac1f\)

Variables

Symbol Meaning SI unit
\(\varepsilon_r\) Relative permittivity -
\(\kappa\) Electrical conductivity (pS/m) -
\(f\) Fraction of charge remaining -
\(\tau\) Relaxation time constant s
\(t_f\) Time to fall to the fraction s
\(\text{class}\) 1 = low-conductivity (≤ 50 pS/m) accumulator -

Method and standards

Ohmic charge relaxation.

Where it is used

  • Tank filling and solvent handling.

Common mistakes

  • Using conductivity in µS/cm without converting (1 µS/cm = 10⁸ pS/m).

Assumptions and limits

  • Ohmic relaxation; hyperbolic relaxation at very low conductivity is slower.

References

  • Charge relaxation τ = ε_r ε₀/κ (electrostatics; Perry's sec. 23 on static electricity)

Questions and answers

Why does conductivity matter?

Charge leaks away through the liquid; poorly conducting liquids keep it long enough to spark.

What is a static accumulator?

A liquid below about 50 pS/m, such as toluene, diesel or hexane.

How can relaxation be helped?

Antistatic additives raise conductivity; relaxation tanks give time before the liquid reaches a tank.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.