FireCADCalc

Runaway Reaction: Adiabatic Temperature Rise and Phi Factor

Adiabatic temperature rise of a reacting mass, the maximum temperature it can reach, and the correction of a test-cell result to plant scale by the phi factor.

Process steam and utilitiesDistillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 1.5 MJ/kg reactant at 30 %, 10 g sample in 8 g cellStrong exotherm, ARC bomb

Results

Adiabatic: no heat loss and full conversion of the limiting reactant. Large plant reactors have a phi factor of about 1.1 or less; a test with a high phi factor understates the plant's temperature rise.

A screening estimate for training and early design, not a hazard or risk study.

A temperature rise above about 50 K is commonly treated as a high severity runaway.

Adiabatic temperature rise225.00K
Maximum temperature after full conversion305.00°C
Phi factor of the test1.9200
Test result corrected to plant scale153.60K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1.5 MJ/kg reactant at 30 %, 10 g sample in 8 g cell. The inputs, in the units selected above:

InputValue
Heat of reaction (released, per kg of reactant)1,500.0 kJ/kg
Mass fraction of reactant in the mixture30.000 %
Specific heat of the mixture2.5000 kJ/(kg·K)
Starting temperature60.000 °C
Sample mass in the test cell0.010000 kg
Test cell mass0.008000 kg
Test cell specific heat0.46000 kJ/(kg·K)
Temperature rise measured in the test120.00 K

Applying the formula below gives:

ResultValue
Adiabatic temperature rise180.00 K
Maximum temperature after full conversion240.00 °C
Phi factor of the test1.1472
Test result corrected to plant scale137.66 K

Open this example in the calculator and change any input.

Formula

\(\Delta T_{ad} = \frac{(-\Delta H_r)x}{C_p}, \quad T_{max} = T_0 + \Delta T_{ad}, \quad \phi = 1 + \frac{m_cC_{p,c}}{m_sC_p}\)

Variables

Symbol Meaning SI unit
\(-\Delta H_r\) Heat of reaction (released, per kg of reactant) J/kg
\(x\) Mass fraction of reactant in the mixture -
\(C_p\) Specific heat of the mixture J/(kg·K)
\(T_0\) Starting temperature K
\(m_s\) Sample mass in the test cell kg
\(m_c\) Test cell mass kg
\(C_{p,c}\) Test cell specific heat J/(kg·K)
\(\Delta T_{meas}\) Temperature rise measured in the test K
\(\Delta T_{ad}\) Adiabatic temperature rise K
\(T_{max}\) Maximum temperature after full conversion K
\(\phi\) Phi factor of the test -
\(\phi\Delta T_{meas}\) Test result corrected to plant scale K

Method and standards

Adiabatic heat balance and the phi factor.

Where it is used

  • Batch reactor safety reviews.
  • Interpreting ARC and ARSST results.

Common mistakes

  • Using a measured rise without the phi correction.
  • Ignoring secondary decompositions.

Assumptions and limits

  • Adiabatic; full conversion.

References

  • Crowl and Louvar
  • Chemical Process Safety: Fundamentals with Applications
  • 2nd ed. (Prentice Hall, 2002)
  • ch. 8
  • eq. 8-1 (phi factor) and adiabatic heat balance

Questions and answers

What is the phi factor?

The ratio of the total heat capacity of sample plus test cell to that of the sample; part of the reaction heat warms the cell, so the measured rise is too low by this factor.

Why does it matter?

The maximum temperature decides whether solvent boils, gases form or a secondary decomposition starts.

What do the defaults represent?

A reaction releasing 1.5 MJ per kg of reactant at 30 % in the mixture, starting at 60 °C, with a 10 g sample in an 8 g steel cell.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.