FireCADCalc

Explosion and Fire Probits: Overpressure and Thermal Dose

Probability of lung-haemorrhage death, eardrum rupture, structural damage and glass breakage from a peak overpressure, and of burn death from thermal dose.

Process steam and utilitiesDistillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 21,400 Pa (Crowl and Louvar Example 2-5), 12.5 kW/m² for 30 s100 kPa, 37.5 kW/m² for 20 s5 kPa, 5 kW/m² for 60 s

Results

Probit equations from Eisenberg et al. as listed by Crowl and Louvar; they describe average populations and open-air exposure. People can escape radiation, which shortens the effective exposure.

A screening estimate for training and early design, not a hazard or risk study.

Deaths from lung haemorrhage0%
Eardrum rupture0.001579%
Structural damage0.004251%
Glass breakage74.632%
Burn deaths from flash or pool fire0.004338%
Burn probit1.0751

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 21,400 Pa (Crowl and Louvar Example 2-5), 12.5 kW/m² for 30 s. The inputs, in the units selected above:

InputValue
Peak overpressure21.400 kPa
Thermal radiation intensity12.500 kW/m²
Exposure time to the radiation30.000 s

Applying the formula below gives:

ResultValue
Deaths from lung haemorrhage0 %
Eardrum rupture8.7599 %
Structural damage62.390 %
Glass breakage100.000 %
Burn deaths from flash or pool fire0.50588 %
Burn probit2.4282

Open this example in the calculator and change any input.

Formula

\(Y = k_1 + k_2\ln V, \quad P = 50\left[1 + \frac{Y - 5}{|Y - 5|}\operatorname{erf}\frac{|Y - 5|}{\sqrt2}\right]\)

\(V = p^o\ (\text{lung: } -77.1, 6.91;\ \text{eardrum: } -15.6, 1.93;\ \text{structure: } -23.8, 2.92;\ \text{glass: } -18.1, 2.79), \quad V_{burn} = \frac{t_eI^{4/3}}{10^4}\ (-14.9, 2.56)\)

Variables

Symbol Meaning SI unit
\(p^o\) Peak overpressure Pa
\(I\) Thermal radiation intensity W/m²
\(t_e\) Exposure time to the radiation s
\(P_{lung}\) Deaths from lung haemorrhage -
\(P_{ear}\) Eardrum rupture -
\(P_{struct}\) Structural damage -
\(P_{glass}\) Glass breakage -
\(P_{burn}\) Burn deaths from flash or pool fire -
\(Y_{burn}\) Burn probit -

Method and standards

Probit model with Eisenberg's constants (p in Pa, I in W/m², t in s).

Where it is used

  • Consequence screening for layouts and emergency planning.
  • Training.

Common mistakes

  • Using kPa in the probit.
  • Treating the result as an individual's risk.

Assumptions and limits

  • Average population; no shelter.

References

  • Crowl and Louvar
  • Chemical Process Safety: Fundamentals with Applications
  • 2nd ed. (Prentice Hall, 2002)
  • ch. 2
  • Table 2-5 and eq. 2-6 (Eisenberg probits)

Questions and answers

What is a probit?

A transformed probability: Y = 5 is 50 %, and each unit of Y is one standard deviation of a normal distribution.

Why is overpressure in pascals?

The constants were fitted with overpressure in N/m² (Pa), radiation in W/m² and time in seconds; the calculator converts for you.

What do the defaults represent?

Crowl and Louvar's Example 2-5 overpressure of 21,400 Pa, and 12.5 kW/m² for 30 s.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.