Worked example
Example: Illustrative pentane and benzene. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heat of vaporisation of liquid 1 | 31.500 kJ/mol |
| Molar mass of liquid 1 | 72.150 kg/kmol |
| Density of liquid 1 | 626.00 kg/m³ |
| Heat of vaporisation of liquid 2 | 33.900 kJ/mol |
| Molar mass of liquid 2 | 78.110 kg/kmol |
| Density of liquid 2 | 876.50 kg/m³ |
| Temperature | 25.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Solubility parameter of liquid 1 (MPa^½) | 15.868 |
| Solubility parameter of liquid 2 (MPa^½) | 18.777 |
| Difference (MPa^½) | 2.9092 |
| Flory–Huggins parameter on the molar volume of liquid 1 (+0.34) | 0.73349 |
Open this example in the calculator and change any input.
Formula
\(\delta = \sqrt{\frac{\Delta H_v - RT}{V_m}}, \quad \chi = 0.34 + \frac{V_1(\delta_1 - \delta_2)^2}{RT}\)
Variables
| Symbol | Meaning | SI unit | |
|---|---|---|---|
| \(\Delta H_{v1}\) | Heat of vaporisation of liquid 1 | J/mol | |
| \(M_1\) | Molar mass of liquid 1 | kg/kmol | |
| \(\rho_1\) | Density of liquid 1 | kg/m³ | |
| \(\Delta H_{v2}\) | Heat of vaporisation of liquid 2 | J/mol | |
| \(M_2\) | Molar mass of liquid 2 | kg/kmol | |
| \(\rho_2\) | Density of liquid 2 | kg/m³ | |
| \(T\) | Temperature | K | |
| \(\delta_1\) | Solubility parameter of liquid 1 (MPa½) | - | |
| \(\delta_2\) | Solubility parameter of liquid 2 (MPa½) | - | |
| \(\Delta\delta\) | Difference (MPa^½) | - | |
| \(\chi\) | Flory–Huggins parameter on the molar volume of liquid 1 (+0.34) | - |
Method and standards
Solubility parameter.
Where it is used
- Solvent and cleaning-agent selection.
- Polymer–solvent compatibility.
Common mistakes
- Using the heat of vaporisation at the boiling point for room-temperature δ.
- Applying δ alone to strongly polar liquids.
Assumptions and limits
- Regular-solution theory; non-polar liquids.
References
- Hildebrand solubility parameter and Flory–Huggins interaction parameter
Questions and answers
What is the solubility parameter of water?
About 47.8 MPa^½, far from most organic liquids, which is why they do not mix.
What units are used?
MPa^½ here; (cal/cm³)½ is MPa½ divided by 2.046.
What do the defaults represent?
n-Pentane and benzene at 25 °C.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Barton, CRC Handbook of Solubility Parameters and Other Cohesion Parameters, 2nd ed. (CRC Press, 1991)