FireCADCalc

Natural Gas Z-Factor, Density, Bg and Viscosity from Gas Gravity

Pseudo-critical properties of a natural gas from its gravity (Standing), Z by Hall–Yarborough, density, gas formation volume factor and Lee–Gonzalez–Eakin viscosity.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliserFuel oil and gas system

Inputs

Examples: 0.7 natural gas, 2000 psia, 150 °F0.65 gas, 1000 psia, 100 °FCondensate gas 0.85, 4000 psia, 220 °F

Results

Sweet gas: with more than a few per cent CO₂ or H₂S, apply the Wichert–Aziz correction to the pseudo-critical properties first. Standing's correlation suits gravities up to about 0.75 for natural gas; Sutton's mixing rules suit heavier gases. B_g is at 14.7 psia and 60 °F.

Pseudo-critical temperature-65.390°C
Pseudo-critical pressure670.91psi
Pseudo-reduced temperature1.4966
Pseudo-reduced pressure1.4905
Compressibility factor0.85765
Gas density58.537kg/m³
Gas formation volume factor (reservoir m³ per standard m³)0.013569m³/m³
Gas viscosity (Lee–Gonzalez–Eakin)0.013120cP

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 0.7 natural gas, 2000 psia, 150 °F. The inputs, in the units selected above:

InputValue
Gas gravity (air = 1)0.70000 -
Gas typeNatural gas
Pressure (absolute)2,000.0 psi
Temperature65.556 °C

Applying the formula below gives:

ResultValue
Pseudo-critical temperature-56.831 °C
Pseudo-critical pressure669.12 psi
Pseudo-reduced temperature1.5658
Pseudo-reduced pressure2.9890
Compressibility factor0.81003
Gas density122.54 kg/m³
Gas formation volume factor (reservoir m³ per standard m³)0.006980 m³/m³
Gas viscosity (Lee–Gonzalez–Eakin)0.016923 cP

Open this example in the calculator and change any input.

Formula

\(T_{pc} = 168 + 325\gamma_g - 12.5\gamma_g^2, \quad p_{pc} = 677 + 15\gamma_g - 37.5\gamma_g^2\ (\text{°R, psia})\)

\(B_g = 0.02827\frac{ZT}{p}, \quad \mu_g = 10^{-4}K\exp\left[X\left(\frac{\rho_g}{62.4}\right)^Y\right]\)

Variables

Symbol Meaning SI unit
\(\gamma_g\) Gas gravity (air = 1) -
\(\text{type}\) Gas type -
\(p\) Pressure (absolute) Pa
\(T\) Temperature K
\(T_{pc}\) Pseudo-critical temperature K
\(p_{pc}\) Pseudo-critical pressure Pa
\(T_{pr}\) Pseudo-reduced temperature -
\(p_{pr}\) Pseudo-reduced pressure -
\(Z\) Compressibility factor -
\(\rho_g\) Gas density kg/m³
\(B_g\) Gas formation volume factor (reservoir m³ per standard m³) m³/m³
\(\mu_g\) Gas viscosity (Lee–Gonzalez–Eakin) Pa·s

Method and standards

Standing's pseudo-critical properties (natural gas: 168 + 325γ − 12.5γ² °R, 677 + 15γ − 37.5γ² psia; condensate: 187 + 330γ − 71.5γ², 706 − 51.7γ − 11.1γ²); Hall–Yarborough Z by root search; Lee–Gonzalez–Eakin viscosity with K = (9.4 + 0.02M)T^1.5/(209 + 19M + T), X = 3.5 + 986/T + 0.01M, Y = 2.4 − 0.2X (T °R, ρ lb/ft³). Ahmed's eq. 2-19 prints 667 for the constant; his worked examples and Standing use 677.

Where it is used

  • Gas in place and reserves.
  • Pipeline and well calculations needing Z and viscosity.

Common mistakes

  • Using it for sour gas without correction.
  • Using gauge pressure.

Assumptions and limits

  • Hall–Yarborough range 1.05 ≤ T_pr ≤ 3.

References

  • Ahmed
  • Reservoir Engineering Handbook
  • 5th ed. (Gulf Professional Publishing, 2019)
  • ch. 2: Standing pseudo-critical properties (eqs. 2-18 to 2-21)
  • Hall–Yarborough Z
  • B_g (eq. 2-53)
  • Lee–Gonzalez–Eakin viscosity (eqs. 2-62 to 2-65)

Questions and answers

When should I use the condensate line?

For gases that come with liquid condensate (rich gas, gravity above about 0.75); the pseudo-critical properties differ.

What is B_g used for?

It converts surface gas volumes to reservoir volumes: gas in place, material balance and well deliverability.

What do the defaults represent?

A 0.7-gravity natural gas at 2,000 psia and 150 °F.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.