FireCADCalc

Hydrate Inhibitor Dose: Hammerschmidt and Nielsen–Bucklin

Inhibitor concentration in the water phase to lower the hydrate temperature below the line temperature (Hammerschmidt, Nielsen–Bucklin) and the inhibitor rate.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserFuel oil and gas system

Inputs

Examples: Mokhatab Example 3-3, methanolMEG, 20 °F depressionDEG, 15 °F

Results

Inhibitor in the water phase only: methanol also vaporises into the gas and dissolves in condensate, so the injected rate is higher. Hammerschmidt suits up to about 20–25 % methanol or 60–70 % glycol by weight; Nielsen–Bucklin is recommended for 25–50 % methanol.

Hydrate depression needed8.3333K
Inhibitor in the water phase (Hammerschmidt)26.696%
Inhibitor in the water phase (Nielsen–Bucklin)41.951%
Inhibitor rate to the water phase (Hammerschmidt)18.209kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Mokhatab Example 3-3, methanol. The inputs, in the units selected above:

InputValue
Hydrate formation temperature without inhibitor29.158 °C
Lowest line temperature9.4000 °C
InhibitorMethanol
Free water in the line100.00 kg/h

Applying the formula below gives:

ResultValue
Hydrate depression needed19.758 K
Inhibitor in the water phase (Hammerschmidt)32.796 %
Inhibitor in the water phase (Nielsen–Bucklin)35.963 %
Inhibitor rate to the water phase (Hammerschmidt)48.801 kg/h

Open this example in the calculator and change any input.

Formula

\(W = \frac{100\,M\Delta T}{K + M\Delta T}\ (\Delta T\ \text{in °F}), \quad \Delta T = -129.6\ln x_{H_2O}\)

Variables

Symbol Meaning SI unit
\(T_h\) Hydrate formation temperature without inhibitor K
\(T_l\) Lowest line temperature K
\(\text{inhibitor}\) Inhibitor -
\(\dot m_w\) Free water in the line kg/s
\(\Delta T\) Hydrate depression needed K
\(W\) Inhibitor in the water phase (Hammerschmidt) -
\(W_{NB}\) Inhibitor in the water phase (Nielsen–Bucklin) -
\(\dot m_i\) Inhibitor rate to the water phase (Hammerschmidt) kg/s

Method and standards

Hammerschmidt (1934) and Nielsen–Bucklin (1983).

Where it is used

  • Well and flowline start-up and shut-in.
  • Continuous MEG injection design.

Common mistakes

  • Forgetting losses to the gas phase.
  • Using °C in the Hammerschmidt constant (it is for °F).

Assumptions and limits

  • Water-phase concentration only.

References

  • Mokhatab
  • Poe and Speight
  • Handbook of Natural Gas Transmission and Processing (Gulf Professional Publishing, 2006)
  • ch. 3
  • eqs. 3-54 and 3-55
  • Table 3-6
  • Example 3-3

Questions and answers

Methanol or glycol?

Methanol is cheap and works at low temperature but is lost to the gas; MEG is recovered and reused in continuous injection.

Why two results?

Hammerschmidt is reliable at moderate concentrations; Nielsen–Bucklin holds for higher methanol concentrations, up to about 50 %.

What do the defaults represent?

Mokhatab's Example 3-3: hydrate point 84.485 °F, line down to 48.92 °F, methanol (32.8 % by Hammerschmidt).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.