Worked example
Example: Menon Example 1: 250 MMSCFD, NPS 20, 1000 psig. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas flow at base conditions | 7,079,212 m³/d |
| Gas pressure (absolute) | 6,996.1 kPa |
| Gas temperature | 15.556 °C |
| Compressibility factor | 0.90000 - |
| Gas gravity (air = 1) | 0.60000 - |
| Pipe inside diameter | 482.60 mm |
| Erosional constant (US customary, 100 for continuous service) | 100.00 - |
| Base temperature | 15.556 °C |
| Base pressure | 101.35 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gas density at flowing conditions | 56.279 kg/m³ |
| Gas velocity | 5.8402 m/s |
| Erosional velocity | 16.261 m/s |
| Velocity as a share of erosional | 35.915 % |
Open this example in the calculator and change any input.
Formula
\(\rho = \frac{P\,G\,M_{air}}{ZRT}, \quad u = \frac{Q_b}{A}\frac{P_b}{P}\frac{T}{T_b}Z, \quad u_{max} = \frac{C}{\sqrt{\rho}}\ (\text{ft/s},\ \rho\ \text{in lb/ft}^3)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_b\) | Gas flow at base conditions | m³/s |
| \(P\) | Gas pressure (absolute) | Pa |
| \(T\) | Gas temperature | K |
| \(Z\) | Compressibility factor | - |
| \(G\) | Gas gravity (air = 1) | - |
| \(D\) | Pipe inside diameter | m |
| \(C\) | Erosional constant (US customary, 100 for continuous service) | - |
| \(T_b\) | Base temperature | K |
| \(P_b\) | Base pressure | Pa |
| \(\rho\) | Gas density at flowing conditions | kg/m³ |
| \(u\) | Gas velocity | m/s |
| \(u_{max}\) | Erosional velocity | m/s |
| \(u/u_{max}\) | Velocity as a share of erosional | - |
Method and standards
Gas law and the erosional velocity relation as given by Menon (C = 100). Air molar mass 28.9647 kg/kmol.
Where it is used
- Line sizing and checking velocity at the delivery end.
- Station piping and headers.
Common mistakes
- Using the base-condition flow as the actual flow.
- Applying C = 100 to sandy or wet gas.
Assumptions and limits
- Z = 1 at base conditions; ideal mixing rule for gravity.
References
- Menon
- Gas Pipeline Hydraulics (CRC Press, 2005)
- ch. 2
- eqs. 2.24–2.31
Questions and answers
Why is the velocity highest at the outlet?
Pressure falls along the line, so the same mass of gas takes more volume and moves faster.
What velocity is acceptable?
Up to about half the erosional velocity; in practice 10–20 m/s in transmission lines.
What do the defaults represent?
Menon's Example 1: 250 MMSCFD (7.08 million m³/day) in a 19-inch bore line at 1,000 psig and 60 °F, Z = 0.9.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.