Worked example
Example: IGT, Menon Example 20. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flow equation | IGT |
| Inlet pressure (absolute) | 7,101.0 kPa |
| Outlet pressure (absolute) | 5,601.0 kPa |
| Pipe inside diameter | 388.00 mm |
| Pipe length | 24.000 km |
| Inlet elevation | 0 m |
| Outlet elevation | 0 m |
| Gas gravity (air = 1) | 0.60000 - |
| Average gas temperature | 19.850 °C |
| Compressibility factor | 0.90000 - |
| Pipeline efficiency | 95.000 % |
| Gas viscosity (IGT and Mueller only) | 0.011900 cP |
| Base temperature | 14.850 °C |
| Base pressure | 101.00 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gas flow at base conditions | 7,665,328 m³/d |
| Average pressure | 6,380.5 kPa |
| Equivalent length for elevation | 24.000 km |
| Gas velocity at the inlet | 9.7720 m/s |
| Gas velocity at the outlet | 12.389 m/s |
Open this example in the calculator and change any input.
Formula
\(Q_b = C\,E\left(\frac{T_b}{P_b}\right)^{a}\left(\frac{P_1^2 - e^sP_2^2}{G^{b}T_fL_eZ}\right)^{c}D^{n}\)
\(s = 0.0684\,G\frac{H_2 - H_1}{T_fZ}, \quad L_e = L\frac{e^s - 1}{s}, \quad P_{avg} = \tfrac23\left(P_1 + P_2 - \frac{P_1P_2}{P_1 + P_2}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{eq.}\) | Flow equation | - |
| \(P_1\) | Inlet pressure (absolute) | Pa |
| \(P_2\) | Outlet pressure (absolute) | Pa |
| \(D\) | Pipe inside diameter | m |
| \(L\) | Pipe length | m |
| \(H_1\) | Inlet elevation | m |
| \(H_2\) | Outlet elevation | m |
| \(G\) | Gas gravity (air = 1) | - |
| \(T_f\) | Average gas temperature | K |
| \(Z\) | Compressibility factor | - |
| \(E\) | Pipeline efficiency | - |
| \(\mu\) | Gas viscosity (IGT and Mueller only) | Pa·s |
| \(T_b\) | Base temperature | K |
| \(P_b\) | Base pressure | Pa |
| \(Q_b\) | Gas flow at base conditions | m³/s |
| \(P_{avg}\) | Average pressure | Pa |
| \(L_e\) | Equivalent length for elevation | m |
| \(u_1\) | Gas velocity at the inlet | m/s |
| \(u_2\) | Gas velocity at the outlet | m/s |
Method and standards
The constants and exponents are those of Menon's SI forms (Q in m³/day at base conditions, P in kPa, D in mm, L in km, T in K): Weymouth C = 3.7435×10⁻³, n = 2.667; Panhandle A C = 4.5965×10⁻³, a = 1.0788, b = 0.8539, c = 0.5394, n = 2.6182; Panhandle B C = 1.002×10⁻², a = 1.02, b = 0.961, c = 0.51, n = 2.53; IGT C = 1.2822×10⁻³, b = 0.8, c = 0.555, n = 2.667 with μ0.2 (poise) in place of Z; Spitzglass C = 1.0815×10⁻², with (1 + 91.44/D + 0.0012D) beside Z; Mueller (b = 0.7391, c = 0.575, n = 2.725, with μ0.2609 in place of Z) and Fritzsche (b = 0.8587, c = 0.538, n = 2.69, no Z) use Menon's US-unit forms, eqs. 2.69 and 2.71 (C = 85.7368 and 410.1688; SCFD, psia, inch, mile, °R, μ in lb/(ft·s)), because his SI constants for these two do not agree with the US forms (by a factor of about 22 and 1,000). The elevation term e^s is applied to all seven.
Where it is used
- Checking the capacity of an existing gas line.
- Comparing the classic equations for a new transmission or plant fuel-gas line.
Common mistakes
- Entering gauge pressures: all pressures are absolute.
- Using Panhandle outside its Reynolds number range.
- Forgetting that Weymouth is conservative and under-predicts flow in large lines.
Assumptions and limits
- Steady, isothermal flow; constant Z at the average pressure.
- Single slope between inlet and outlet for the elevation correction.
References
- Menon
- Gas Pipeline Hydraulics (CRC Press, 2005)
- ch. 2
- eqs. 2.9–2.14
- 2.29
- 2.54
- 2.56
- 2.60
- 2.64
- 2.68
- 2.69
- 2.71
Questions and answers
Which equation should I use?
Weymouth is conservative and suits gathering lines; Panhandle A and B suit long transmission lines; IGT, Mueller and Spitzglass suit distribution and fuel-gas piping. The AGA method with roughness is the most general.
What is pipeline efficiency?
A factor of about 0.88–0.95 that matches the empirical equation to measured flows; it stands in for roughness, bends and fittings.
What do the defaults represent?
Menon's Example 20: a DN 400 line, 24 km long, 7,000 to 5,500 kPa gauge, gas gravity 0.6 at 20 °C, by the IGT equation (7.67 million m³/day).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.