FireCADCalc

Gas Pipeline Inlet Pressure by the AGA Transmission Factor

Inlet pressure a gas pipeline needs for a flow and delivery pressure, using the AGA fully and partially turbulent transmission factors and the general flow equation.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserFuel oil and gas system

Inputs

Examples: Menon Example 12: 6 Mm3/day, DN 500, 60 kmPlant supply, 300 mm, 15 km, 100 m riseCoated line, smooth-pipe zone governs

Results

The fully turbulent (rough pipe) factor governs.

Z should be taken at the average pressure; repeat with Z at the new average pressure if the inlet pressure changed much. Drag factor about 0.96 for an average bend index of 60–80°.

Reynolds number5,087,716
Fully turbulent transmission factor17.530
Von Kármán smooth-pipe transmission factor20.942
Partially turbulent transmission factor19.895
AGA transmission factor (smaller of the two)17.530
Darcy friction factor, 4/F²0.013016
Inlet pressure needed (absolute)3,055.8kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Menon Example 12: 6 Mm3/day, DN 500, 60 km. The inputs, in the units selected above:

InputValue
Gas flow at base conditions6,000,000 m³/d
Delivery pressure (absolute)5,000.0 kPa
Pipe inside diameter476.00 mm
Pipe length60.000 km
Pipe roughness0.020000 mm
Pipe drag factor (bends and fittings)0.96000 -
Inlet elevation0 m
Outlet elevation0 m
Gas gravity (air = 1)0.60000 -
Gas viscosity0.012000 cP
Average gas temperature19.850 °C
Compressibility factor0.85000 -
Base temperature14.850 °C
Base pressure101.00 kPa

Applying the formula below gives:

ResultValue
Reynolds number1.1347e+07
Fully turbulent transmission factor19.779
Von Kármán smooth-pipe transmission factor22.232
Partially turbulent transmission factor21.342
AGA transmission factor (smaller of the two)19.779
Darcy friction factor, 4/F²0.010225
Inlet pressure needed (absolute)6,129.6 kPa

Open this example in the calculator and change any input.

Formula

\(F_r = 4\log_{10}\frac{3.7D}{e}, \quad F_t = 4\log_{10}\frac{Re}{F_t} - 0.6, \quad F_p = 4D_f\log_{10}\frac{Re}{1.4125F_t}\)

\(Q_b = 5.747\times10^{-4}F\frac{T_b}{P_b}\left(\frac{P_1^2 - e^sP_2^2}{GT_fL_eZ}\right)^{0.5}D^{2.5}\)

Variables

Symbol Meaning SI unit
\(Q_b\) Gas flow at base conditions m³/s
\(P_2\) Delivery pressure (absolute) Pa
\(D\) Pipe inside diameter m
\(L\) Pipe length m
\(e\) Pipe roughness m
\(D_f\) Pipe drag factor (bends and fittings) -
\(H_1\) Inlet elevation m
\(H_2\) Outlet elevation m
\(G\) Gas gravity (air = 1) -
\(\mu\) Gas viscosity Pa·s
\(T_f\) Average gas temperature K
\(Z\) Compressibility factor -
\(T_b\) Base temperature K
\(P_b\) Base pressure Pa
\(Re\) Reynolds number -
\(F_r\) Fully turbulent transmission factor -
\(F_t\) Von Kármán smooth-pipe transmission factor -
\(F_p\) Partially turbulent transmission factor -
\(F\) AGA transmission factor (smaller of the two) -
\(f\) Darcy friction factor, 4/F² -
\(P_1\) Inlet pressure needed (absolute) Pa

Method and standards

AGA NB-13 transmission factors in the general flow equation, in Menon's SI form (Q m³/day, P kPa, D mm, L km, T K; Re = 0.5134 (P_b/T_b)(GQ/μD) with μ in poise).

Where it is used

  • Sizing a new gas transmission or plant supply line.
  • Checking the pressure a compressor must deliver.

Common mistakes

  • Using gauge pressures.
  • Using Z at the inlet instead of the average pressure.

Assumptions and limits

  • Steady isothermal flow; single slope.

References

  • Menon
  • Gas Pipeline Hydraulics (CRC Press, 2005)
  • ch. 2
  • eqs. 2.8
  • 2.35 and 2.48–2.51 (AGA NB-13 method)

Questions and answers

Why two transmission factors?

AGA computes a rough-pipe value and a smooth-pipe value reduced by the drag factor, and uses the smaller one, so the flow regime chooses itself.

What drag factor should I use?

About 0.96 for bare steel with an average number of bends (bend index 60–80°), 0.975 for very few bends and 0.90–0.93 for very many.

What do the defaults represent?

Menon's Example 12: 6 million m³/day through a DN 500 line (476 mm bore), 60 km, 5 MPa delivery; the inlet needs about 6.13 MPa.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.