Arps Decline Curve: Rate and Cumulative Production

Production rate and cumulative production after a time by Arps' exponential, hyperbolic or harmonic decline, from initial rate, decline rate and exponent b.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Hyperbolic b 0.5, 40 %/yr, 3 yearsExponential 15 %/yr, 5 yearsHarmonic, 2 years

Results

D_i is the nominal (instantaneous) decline rate; the effective first-year decline is shown for comparison. Arps' relations hold for boundary-dominated flow at constant bottom-hole pressure.

Rate at time t363.64bbl/d
Cumulative production to time t383,979bbl
Effective annual decline in the first year37.500%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hyperbolic b 0.5, 40 %/yr, 3 years. The inputs, in the units selected above:

InputValue
Initial rate1,000.0 bbl/d
Initial decline rate (nominal)0.40000 1/a
Decline exponent (0 exponential, 1 harmonic)0.50000 -
Time3.0000 a

Applying the formula below gives:

ResultValue
Rate at time t390.62 bbl/d
Cumulative production to time t684,844 bbl
Effective annual decline in the first year30.556 %

Open this example in the calculator and change any input.

Formula

\(q = \frac{q_i}{(1 + bD_it)^{1/b}}, \quad N_p = \frac{q_i^b}{(1 - b)D_i}\left(q_i^{1-b} - q^{1-b}\right)\)

\(q = q_ie^{-D_it},\ N_p = \frac{q_i - q}{D_i}\ (b = 0); \quad N_p = \frac{q_i}{D_i}\ln\frac{q_i}{q}\ (b = 1)\)

Variables

Symbol Meaning SI unit
\(q_i\) Initial rate m³/s
\(D_i\) Initial decline rate (nominal) 1/s
\(b\) Decline exponent (0 exponential, 1 harmonic) -
\(t\) Time s
\(q(t)\) Rate at time t m³/s
\(N_p\) Cumulative production to time t m³
\(D_e\) Effective annual decline in the first year -

Method and standards

Arps' decline relations.

Where it is used

  • Reserve and production forecasts.
  • Economic limit and well life.

Common mistakes

  • Mixing nominal and effective decline.
  • Using b > 1 data from transient flow.

Assumptions and limits

  • Boundary-dominated flow; constant operating conditions.

References

  • Ahmed
  • Reservoir Engineering Handbook
  • 5th ed. (Gulf Professional Publishing, 2019)
  • ch. 16 (Arps, 1945)

Questions and answers

Which b should I use?

0 (exponential) for conservative forecasts and strong pressure depletion; 0.3–0.6 for solution-gas drive; near 1 with good pressure support.

What is the difference between nominal and effective decline?

Nominal is the instantaneous rate; effective is the fall over a year: for exponential decline D_e = 1 − e^(−D_i).

What do the defaults represent?

1,000 bbl/d declining hyperbolically (b = 0.5) at 40 % per year nominal, after 3 years.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.