Worked example
Example: 20 m3/h whey 6 % to 18 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Feed | 20.000 m³/h |
| Feed total solids | 6.0000 % |
| Target retentate solids | 18.000 % |
| Solids rejection | 99.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Retentate | 6.6221 m³/h |
| Permeate | 13.378 m³/h |
| Volume concentration factor | 3.0202 |
| Permeate solids | 0.060000 % |
Open this example in the calculator and change any input.
Formula
\(x_P = x_F(1 - R), \quad \dot V_R = \dot V_F\frac{x_F - x_P}{x_R - x_P}, \quad VCF = \frac{\dot V_F}{\dot V_R}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_F\) | Feed | m³/s |
| \(x_F\) | Feed total solids | - |
| \(x_R\) | Target retentate solids | - |
| \(R\) | Solids rejection | - |
| \(\dot V_R\) | Retentate | m³/s |
| \(\dot V_P\) | Permeate | m³/s |
| \(VCF\) | Volume concentration factor | - |
| \(x_P\) | Permeate solids | - |
Method and standards
Solids balance (densities taken equal).
Where it is used
- Membrane plant sizing.
Common mistakes
- Ignoring density differences at high solids.
Assumptions and limits
- Equal densities; constant rejection. An 18 % concentrate is several per cent denser than permeate, so the retentate volume is slightly overstated.
- Retentate solids above about 22 %, the practical RO limit for whey quoted in the FAQ, are flagged.
References
- Mass and energy balances (definitions): solids balance with a solids rejection
Questions and answers
Why concentrate whey by RO?
It removes water at a fraction of the energy of evaporation, cutting transport and drying cost.
How far can RO go?
About 18–22 % solids for whey before osmotic pressure and fouling limit it.
What is VCF?
Feed volume divided by retentate volume.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.