Worked example
Example: 5 m3 caustic 15 → 75 °C, 200 kW. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Tank solution volume | 5.0000 m³ |
| Solution density | 1,030.0 kg/m³ |
| Initial temperature | 15.000 °C |
| Cleaning temperature | 75.000 °C |
| Heater duty | 200.00 kW |
| Cycles per day | 3.0000 - |
| Steam latent heat | 2,130.0 kJ/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Energy per cycle | 343.33 kWh |
| Heating time | 103.00 min |
| Steam per cycle | 580.28 kg |
| Steam per day | 1,740.8 kg |
Open this example in the calculator and change any input.
Formula
\(E = V\rho c(T_2 - T_1), \quad t = \frac{E}{\dot Q}, \quad m_s = \frac{E}{h_{fg}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Tank solution volume | m³ |
| \(\rho\) | Solution density | kg/m³ |
| \(T_1\) | Initial temperature | K |
| \(T_2\) | Cleaning temperature | K |
| \(\dot Q\) | Heater duty | W |
| \(n\) | Cycles per day | - |
| \(h_{fg}\) | Steam latent heat | J/kg |
| \(E\) | Energy per cycle | J |
| \(t\) | Heating time | s |
| \(m_s\) | Steam per cycle | kg |
| \(m_d\) | Steam per day | kg |
Method and standards
Sensible heat with c = 4.0 kJ/(kg·K).
Where it is used
- CIP system design.
- Steam and energy audits.
Common mistakes
- Ignoring circuit volume.
- Counting single-use tanks as recovered.
Assumptions and limits
- No heat loss during heating.
References
- Mass and energy balances (definitions); solution specific heat taken as 4.0 kJ/(kg·K)
Questions and answers
What temperature for caustic CIP?
70–80 °C for dairy; acid at 60–70 °C.
Is pipe heat counted?
No: add circuit warm-up and losses for a full cycle.
Why reuse detergent?
The tank is reheated from 50–60 °C instead of cold water.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.