Vacuum (Agitated or Tray) Dryer Batch Drying Time

Batch drying time of a jacketed vacuum dryer from water to remove, boiling temperature at the vacuum (IF97), jacket temperature, area and coefficient.

Chemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: Illustrative 1 t batch at 100 mbarPharma ANFD at 50 mbarPaddle dryer at 300 mbar

Accepted: 1 to 100,000 kg
Accepted: 1 to 500 %
Accepted: 0 to 100 %
Accepted: 1 to 101.33 kPa
Accepted: 26.85 to 226.85 °C
Accepted: 0.1 to 500 m²
Accepted: 5 to 1,000 W/(m²·K)

Results

Under vacuum the moisture boils at a low temperature (from IAPWS-IF97 at the dryer pressure), so heat-sensitive products dry quickly at a mild jacket temperature. The heat flow U A (T_j − T_b) supplies the latent heat of the water removed. U falls as the product dries and loses contact with the wall, so the mean value used should come from trials; this estimate ignores heating up the batch and the slower final stage.

Water to remove400.00kg
Boiling temperature at the dryer pressure69.095°C
Heat flow182.04kW
Drying time1.4254h
Latent heat at the boiling temperature2,335.3kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1 t batch at 100 mbar. The inputs, in the units selected above:

InputValue
Dry solids in the batch1,000.0 kg
Initial moisture (dry basis)40.000 %
Final moisture (dry basis)2.0000 %
Dryer pressure (absolute)10.000 kPa
Jacket (heating medium) temperature120.00 °C
Heated area10.000 m²
Mean overall heat transfer coefficient60.000 W/(m²·K)

Applying the formula below gives:

ResultValue
Water to remove380.00 kg
Boiling temperature at the dryer pressure45.808 °C
Heat flow44.515 kW
Drying time5.6721 h
Latent heat at the boiling temperature2,392.1 kJ/kg

Open this example in the calculator and change any input.

Formula

\(m_w = m_d(X_0 - X_1), \quad \dot Q = UA(T_j - T_b(p)), \quad t = \frac{m_w\lambda}{\dot Q}\)

Variables

Symbol Meaning SI unit
\(m_d\) Dry solids in the batch kg
\(X_0\) Initial moisture (dry basis) -
\(X_1\) Final moisture (dry basis) -
\(p\) Dryer pressure (absolute) Pa
\(T_j\) Jacket (heating medium) temperature K
\(A\) Heated area m²
\(U\) Mean overall heat transfer coefficient W/(m²·K)
\(m_w\) Water to remove kg
\(T_b\) Boiling temperature at the dryer pressure K
\(\dot Q\) Heat flow W
\(t\) Drying time s
\(\lambda\) Latent heat at the boiling temperature J/kg

Method and standards

Vacuum dryer.

Where it is used

  • Pharmaceutical, fine chemical and food batch drying.
  • Choosing vacuum level and jacket temperature.

Common mistakes

  • Using the wet-product U for the whole batch.
  • Forgetting solvent instead of water properties.

Assumptions and limits

  • Water as the liquid; mean U over the batch.

References

  • Contact drying under vacuum with IAPWS-IF97 boiling temperature

Questions and answers

At what temperature does water boil at 100 mbar?

About 46 °C.

Why does drying slow at the end?

Dry product contacts the hot wall poorly and the remaining moisture is bound, so U falls.

What do the defaults represent?

An illustrative 1 t (dry) batch dried from 40 % to 2 % (dry basis) at 100 mbar with a 120 °C jacket, 10 m² and U = 60 W/(m²·K).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.