FireCADCalc

Rotary Dryer Retention Time (Friedman–Marshall)

Retention time of solids in a flighted rotary dryer from length, diameter, slope and speed, corrected for gas drag in co-current or counter-current flow.

Inputs

Examples: Illustrative counter-current dryerCo-current dryer, coarse solidsSmall cooler, fine solids

Accepted: 1 to 100 m
Accepted: 0.3 to 6 m
Accepted: 0 to 20 %
Accepted: 0.47746 to 47.746 rpm
Accepted: 10 to 50,000 µm
Accepted: 0.01 to 20 kg/(m²·s)
Accepted: 0.01 to 50 kg/(m²·s)

Results

Friedman and Marshall's correlation in its original units gives θ = 0.23 L/(S N^0.9 D) ± 0.6 B L G/F minutes, with L and D in ft, N in rpm, G and F in lb/(h·ft²), and B = 5 D_p^−0.5 with D_p in µm. The first term is the cascading of solids down the slope; the second is the drag of the gas, which holds solids back in counter-current flow and pushes them along in co-current flow. Inputs here are SI and converted internally. The correlation came from small pilot dryers: treat it as a first estimate and confirm with the maker.

Retention time from geometry alone18.347min
Correction for the gas flow8.2532min
Retention time26.600min
Particle-size constant B = 5 D_p^−0.50.22361

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative counter-current dryer. The inputs, in the units selected above:

InputValue
Dryer length15.000 m
Shell diameter1.8000 m
Slope (m per m)3.0000 %
Rotational speed4.0000 rpm
Mean particle size500.00 µm
Gas mass velocity1.5000 kg/(m²·s)
Feed rate of dry solids per unit cross-section1.2000 kg/(m²·s)
Gas flowCounter-current (slows the solids)

Applying the formula below gives:

ResultValue
Retention time from geometry alone18.347 min
Correction for the gas flow8.2532 min
Retention time26.600 min
Particle-size constant B = 5 D_p^−0.50.22361

Open this example in the calculator and change any input.

Formula

\(\theta = \frac{0.23\,L}{S N^{0.9} D} \pm \frac{0.6\,B L G}{F}, \quad B = 5 D_p^{-0.5}\ \ \text{(US units)}\)

Variables

Symbol Meaning SI unit
\(L\) Dryer length m
\(D\) Shell diameter m
\(S\) Slope (m per m) -
\(N\) Rotational speed rad/s
\(D_p\) Mean particle size m
\(G\) Gas mass velocity kg/(m²·s)
\(F\) Feed rate of dry solids per unit cross-section kg/(m²·s)
\(\text{flow}\) Gas flow -
\(\theta_0\) Retention time from geometry alone s
\(\Delta\theta_G\) Correction for the gas flow s
\(\theta\) Retention time s
\(B\) Particle-size constant B = 5 D_p^−0.5 -

Method and standards

Retention time.

Where it is used

  • Rotary dryer and cooler design.
  • Checking whether a dryer is long enough.

Common mistakes

  • Using the kiln (Saeman) equation for a flighted dryer.
  • Ignoring the gas drag on fine particles.

Assumptions and limits

  • Flighted dryer; correlation's units converted from SI.

References

  • Friedman–Marshall retention-time correlation

Questions and answers

How do slope and speed affect retention?

Retention time is inversely proportional to slope and to speed to the power 0.9.

Why does counter-current gas lengthen it?

Gas flowing against the solids drags falling particles back up the dryer.

What do the defaults represent?

An illustrative 15 m × 1.8 m counter-current dryer at 3 % slope and 4 rpm, 500 µm solids, gas 1.5 and solids 1.2 kg/(m²·s).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.