FireCADCalc

Timber Kiln Drying: Water Removed and Energy per m³

Water removed and heat used to kiln-dry a charge of timber from its volume, basic density and moisture contents, with the energy per cubic metre.

Inputs

Examples: Illustrative 50 m3 hardwood chargeSoftwood, high temperatureAir-dried stock to 8 %

Accepted: 0.1 to 10,000 m³
Accepted: 200 to 1,200 kg/m³
Accepted: 5 to 200 %
Accepted: 2 to 50 %
Accepted: 1 to 2.5 kJ/(kg·K)
Accepted: 0 to 150 K
Accepted: 2,000 to 3,200 kJ/kg
Accepted: 20 to 100 %

Results

Timber moisture is stated on a dry basis, so the water removed is the oven-dry mass (volume × basic density) times the drop in moisture content. Heat goes to warming the wood and its water, evaporating the water (slightly more than free water below fibre saturation because of sorption heat) and to vent and structure losses, lumped here in the kiln efficiency. Conventional kilns use about 3–6 MJ per kg of water; vented heat recovery or dehumidification kilns use less.

Oven-dry wood mass27.500t
Water removed13,200kg
Heat supplied79.397GJ
Heat per m³ of timber441.09kWh
Heat per kg of water6.0149MJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 50 m3 hardwood charge. The inputs, in the units selected above:

InputValue
Timber volume (green)50.000 m³
Basic density (oven-dry mass per green volume)550.00 kg/m³
Initial moisture (dry basis)60.000 %
Final moisture (dry basis)12.000 %
Specific heat of oven-dry wood1.4000 kJ/(kg·K)
Heating of the charge from ambient to kiln temperature50.000 K
Heat to evaporate wood moisture (including sorption)2,600.0 kJ/kg
Kiln efficiency (venting and structure losses)50.000 %

Applying the formula below gives:

ResultValue
Oven-dry wood mass27.500 t
Water removed13,200 kg
Heat supplied79.397 GJ
Heat per m³ of timber441.09 kWh
Heat per kg of water6.0149 MJ/kg

Open this example in the calculator and change any input.

Formula

\(m_w = V\rho_b(M_0 - M_1), \quad Q = \frac{m_w\lambda + V\rho_b(c_w + c_{water}M_0)\Delta T}{\eta}\)

Variables

Symbol Meaning SI unit
\(V\) Timber volume (green) m³
\(\rho_b\) Basic density (oven-dry mass per green volume) kg/m³
\(M_0\) Initial moisture (dry basis) -
\(M_1\) Final moisture (dry basis) -
\(c_w\) Specific heat of oven-dry wood J/(kg·K)
\(\Delta T\) Heating of the charge from ambient to kiln temperature K
\(\lambda\) Heat to evaporate wood moisture (including sorption) J/kg
\(\eta\) Kiln efficiency (venting and structure losses) -
\(m_d\) Oven-dry wood mass kg
\(m_w\) Water removed kg
\(Q\) Heat supplied J
\(Q/V\) Heat per m³ of timber J
\(Q/m_w\) Heat per kg of water J/kg

Method and standards

Timber kiln.

Where it is used

  • Sawmills and furniture plants.
  • Choosing between conventional and heat pump kilns.

Common mistakes

  • Using wet-basis moisture.
  • Using air-dry density instead of basic density.

Assumptions and limits

  • Single heat-up; lumped losses.

References

  • Energy balance of timber kiln drying

Questions and answers

How much water is in a cubic metre of green timber?

For 550 kg/m³ basic density at 60 % moisture, 330 kg, of which drying to 12 % removes 264 kg.

Why use dry-basis moisture for wood?

It is the trade convention: water per unit of oven-dry wood, which can exceed 100 %.

What do the defaults represent?

An illustrative 50 m³ charge of hardwood (550 kg/m³) dried from 60 % to 12 %, heated 50 K, 50 % kiln efficiency.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.