Worked example
Example: Illustrative 500 kg/h fluid-bed dryer. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water to evaporate | 500.00 kg/h |
| Dry solids rate | 2,000.0 kg/h |
| Specific heat of the solids (with residual moisture) | 1.5000 kJ/(kg·K) |
| Temperature rise of the solids | 40.000 K |
| Air inlet temperature | 150.00 °C |
| Air outlet temperature | 70.000 °C |
| Heat loss as a share of the useful heat | 10.000 % |
| Superficial air velocity in the bed (at inlet temperature) | 0.80000 m/s |
| Bed density (fluidised) | 600.00 kg/m³ |
| Bed depth | 300.00 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Dry air flow | 18,704 kg/h |
| Heat supplied to the air | 425.87 kW |
| Bed (distributor) area | 7.7853 m² |
| Mean solids residence time | 42.040 min |
| Humidity pick-up of the air | 26.733 g/kg |
| Heat per kg of water evaporated | 3,066.2 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(\dot m_a c_p (T_{in} - T_{out}) = (1 + f_L)\left[\dot m_w(h_v - h_l) + \dot m_s c_s \Delta T_s\right], \quad A = \frac{\dot m_a}{\rho_{in} u}, \quad \tau = \frac{\rho_b A H}{\dot m_s}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_w\) | Water to evaporate | kg/s |
| \(\dot m_s\) | Dry solids rate | kg/s |
| \(c_s\) | Specific heat of the solids (with residual moisture) | J/(kg·K) |
| \(\Delta T_s\) | Temperature rise of the solids | K |
| \(T_{in}\) | Air inlet temperature | K |
| \(T_{out}\) | Air outlet temperature | K |
| \(f_L\) | Heat loss as a share of the useful heat | - |
| \(u\) | Superficial air velocity in the bed (at inlet temperature) | m/s |
| \(\rho_b\) | Bed density (fluidised) | kg/m³ |
| \(H\) | Bed depth | m |
| \(\dot m_a\) | Dry air flow | kg/s |
| \(\dot Q\) | Heat supplied to the air | W |
| \(A\) | Bed (distributor) area | m² |
| \(\tau\) | Mean solids residence time | s |
| \(\Delta x\) | Humidity pick-up of the air | kg/kg |
| \(q_w\) | Heat per kg of water evaporated | J/kg |
Method and standards
Fluid-bed dryer.
Where it is used
- Granules, grains, chemicals, pharmaceuticals and tea.
- First sizing before vendor design.
Common mistakes
- Using the velocity at outlet temperature for the area.
- Ignoring the heat to warm the solids.
Assumptions and limits
- Steady state; well-mixed bed; feed water at 20 °C.
References
- Heat balance and hydrodynamic sizing of a continuous fluid-bed dryer
Questions and answers
How is the bed area chosen?
From the air volume at the inlet temperature divided by the fluidising velocity, usually 2–4 times the minimum fluidisation velocity.
Why is the exhaust temperature important?
Air leaving hotter carries away more heat; a lower outlet temperature raises efficiency but risks wet, sticky product.
What do the defaults represent?
An illustrative dryer evaporating 500 kg/h from 2 t/h of solids, air 150 °C in and 70 °C out, 0.8 m/s, 300 mm bed.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)