Worked example
Example: Illustrative 1 t/h at atmospheric pressure. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water evaporated | 1,000.0 kg/h |
| Feed temperature | 20.000 °C |
| Dryer pressure (absolute) | 1.0132 bar |
| Steam outlet temperature | 150.00 °C |
| Dry solids rate | 1,500.0 kg/h |
| Specific heat of the solids | 1.5000 kJ/(kg·K) |
| Share of the excess steam's latent heat recovered | 70.000 % |
| Thermal efficiency of an air dryer for comparison | 55.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat input to the steam loop | 797.90 kW |
| Heat per kg of water | 2,872.4 kJ/kg |
| Heat recovered from the excess steam | 438.77 kW |
| Net heat per kg of water after recovery | 1,292.8 kJ/kg |
| Heat per kg of water in an air dryer | 4,564.1 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m_w\left[h_v(p, T_o) - h_l(T_f)\right] + \dot m_s c_s \Delta T_s, \quad \dot Q_r = f_r\,\dot m_w h_{fg}(p)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_w\) | Water evaporated | kg/s |
| \(T_f\) | Feed temperature | K |
| \(p\) | Dryer pressure (absolute) | Pa |
| \(T_o\) | Steam outlet temperature | K |
| \(\dot m_s\) | Dry solids rate | kg/s |
| \(c_s\) | Specific heat of the solids | J/(kg·K) |
| \(f_r\) | Share of the excess steam's latent heat recovered | - |
| \(\eta_a\) | Thermal efficiency of an air dryer for comparison | - |
| \(\dot Q\) | Heat input to the steam loop | W |
| \(q_w\) | Heat per kg of water | J/kg |
| \(\dot Q_r\) | Heat recovered from the excess steam | W |
| \(q_{net}\) | Net heat per kg of water after recovery | J/kg |
| \(q_a\) | Heat per kg of water in an air dryer | J/kg |
Method and standards
Superheated steam drying.
Where it is used
- Pulp, sludge, bagasse, lignite and timber drying.
- Integrating dryers with plant steam systems.
Common mistakes
- Counting the excess steam as a loss.
- Feeding cold product that condenses steam on its surface.
Assumptions and limits
- Steady state; heat losses not included; air leakage nil.
References
- Energy balance of superheated-steam drying with IAPWS-IF97
Questions and answers
Why can a superheated steam dryer save energy?
The evaporated water leaves as steam that can be condensed elsewhere in the plant, recovering most of its latent heat.
Does the product reach 100 °C?
Yes, at atmospheric pressure the product surface sits near the saturation temperature, which suits pulp, sludge, bagasse and coal, not heat-sensitive food.
What do the defaults represent?
An illustrative dryer evaporating 1 t/h at atmospheric pressure with steam leaving at 150 °C, 1.5 t/h of solids, 70 % of the excess steam's latent heat reused.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)