FireCADCalc

Microwave Drying Power and Energy per kg of Water

Microwave power absorbed and electrical power needed to heat and dry a product stream, from feed rate, moisture contents, specific heat and magnetron efficiency.

Inputs

Examples: Illustrative 100 kg/h feedFinish drying of pastaCeramic ware

Accepted: 0.036 to 36,000 kg/h
Accepted: 1 to 95 %
Accepted: 0 to 90 %
Accepted: 0.5 to 4.5 kJ/(kg·K)
Accepted: 0 to 200 K
Accepted: 2,000 to 2,600 kJ/kg
Accepted: 20 to 100 %

Results

Microwaves heat the water inside the product directly, so the absorbed power must warm the feed to evaporation temperature and supply the latent heat of the water removed. Magnetrons convert 60–80 % of the mains power to microwaves and not all of it is absorbed, so the electrical demand is the absorbed power over the overall efficiency. Microwave drying is fast and uniform but uses expensive electricity: it is usually used to finish products dried mostly by hot air.

Water evaporated33.333kg/h
Microwave power absorbed26.759kW
Electrical power44.599kW
Electricity per kg of water (kWh/kg)1.3380

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 100 kg/h feed. The inputs, in the units selected above:

InputValue
Wet feed rate100.00 kg/h
Feed moisture (wet basis)40.000 %
Product moisture (wet basis)10.000 %
Specific heat of the wet feed2.8000 kJ/(kg·K)
Heating of the feed to evaporation temperature75.000 K
Latent heat2,260.0 kJ/kg
Overall electrical-to-absorbed efficiency60.000 %

Applying the formula below gives:

ResultValue
Water evaporated33.333 kg/h
Microwave power absorbed26.759 kW
Electrical power44.599 kW
Electricity per kg of water (kWh/kg)1.3380

Open this example in the calculator and change any input.

Formula

\(\dot m_w = \dot m_f\frac{w_0 - w_1}{1 - w_1}, \quad P_a = \dot m_f c_p\Delta T + \dot m_w\lambda, \quad P_e = \frac{P_a}{\eta}\)

Variables

Symbol Meaning SI unit
\(\dot m_f\) Wet feed rate kg/s
\(w_0\) Feed moisture (wet basis) -
\(w_1\) Product moisture (wet basis) -
\(c_p\) Specific heat of the wet feed J/(kg·K)
\(\Delta T\) Heating of the feed to evaporation temperature K
\(\lambda\) Latent heat J/kg
\(\eta\) Overall electrical-to-absorbed efficiency -
\(\dot m_w\) Water evaporated kg/s
\(P_a\) Microwave power absorbed W
\(P_e\) Electrical power W
\(SEC\) Electricity per kg of water (kWh/kg) -

Method and standards

Microwave drying.

Where it is used

  • Finish drying of food, pharmaceuticals, ceramics and timber.
  • Comparing microwave with hot-air drying.

Common mistakes

  • Using magnetron rating as absorbed power.
  • Forgetting the heating of the feed.

Assumptions and limits

  • Steady continuous drying; constant properties.

References

  • Energy balance of microwave drying

Questions and answers

How much electricity does microwave drying use?

About 1–1.5 kWh per kg of water, depending on efficiency and preheating.

Why combine microwave with hot air?

Hot air removes surface water cheaply; microwaves drive out the last moisture from inside quickly.

What do the defaults represent?

An illustrative 100 kg/h feed dried from 40 % to 10 % moisture, heated 75 K, 60 % overall efficiency.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.