Worked example
Example: Illustrative 100 kg/h feed. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wet feed rate | 100.00 kg/h |
| Feed moisture (wet basis) | 40.000 % |
| Product moisture (wet basis) | 10.000 % |
| Specific heat of the wet feed | 2.8000 kJ/(kg·K) |
| Heating of the feed to evaporation temperature | 75.000 K |
| Latent heat | 2,260.0 kJ/kg |
| Overall electrical-to-absorbed efficiency | 60.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water evaporated | 33.333 kg/h |
| Microwave power absorbed | 26.759 kW |
| Electrical power | 44.599 kW |
| Electricity per kg of water (kWh/kg) | 1.3380 |
Open this example in the calculator and change any input.
Formula
\(\dot m_w = \dot m_f\frac{w_0 - w_1}{1 - w_1}, \quad P_a = \dot m_f c_p\Delta T + \dot m_w\lambda, \quad P_e = \frac{P_a}{\eta}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_f\) | Wet feed rate | kg/s |
| \(w_0\) | Feed moisture (wet basis) | - |
| \(w_1\) | Product moisture (wet basis) | - |
| \(c_p\) | Specific heat of the wet feed | J/(kg·K) |
| \(\Delta T\) | Heating of the feed to evaporation temperature | K |
| \(\lambda\) | Latent heat | J/kg |
| \(\eta\) | Overall electrical-to-absorbed efficiency | - |
| \(\dot m_w\) | Water evaporated | kg/s |
| \(P_a\) | Microwave power absorbed | W |
| \(P_e\) | Electrical power | W |
| \(SEC\) | Electricity per kg of water (kWh/kg) | - |
Method and standards
Microwave drying.
Where it is used
- Finish drying of food, pharmaceuticals, ceramics and timber.
- Comparing microwave with hot-air drying.
Common mistakes
- Using magnetron rating as absorbed power.
- Forgetting the heating of the feed.
Assumptions and limits
- Steady continuous drying; constant properties.
References
- Energy balance of microwave drying
Questions and answers
How much electricity does microwave drying use?
About 1–1.5 kWh per kg of water, depending on efficiency and preheating.
Why combine microwave with hot air?
Hot air removes surface water cheaply; microwaves drive out the last moisture from inside quickly.
What do the defaults represent?
An illustrative 100 kg/h feed dried from 40 % to 10 % moisture, heated 75 K, 60 % overall efficiency.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.