Worked example
Example: Illustrative 1 t/h of green leaf. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Green leaf rate | 1,000.0 kg/h |
| Green leaf moisture (wet basis) | 78.000 % |
| Withered leaf moisture (wet basis) | 68.000 % |
| Ambient air temperature | 22.000 °C |
| Ambient relative humidity | 80.000 % |
| Air temperature after heating | 30.000 °C |
| Air temperature leaving the leaf bed | 23.000 °C |
| Pressure | 1.0132 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water removed | 312.50 kg/h |
| Dry air flow | 110,182 kg/h |
| Air volume flow at the fan (heated air) | 96,644 m³/h |
| Relative humidity of the air leaving | 90.973 % |
| Heater duty | 252.36 kW |
| Withering loss as a share of green leaf | 31.250 % |
Open this example in the calculator and change any input.
Formula
\(\dot m_w = \dot m_g\frac{w_0 - w_1}{1 - w_1}, \quad h(T_{in}, x_a) = h(T_{out}, x_o), \quad \dot m_a = \frac{\dot m_w}{x_o - x_a}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_g\) | Green leaf rate | kg/s |
| \(w_0\) | Green leaf moisture (wet basis) | - |
| \(w_1\) | Withered leaf moisture (wet basis) | - |
| \(T_a\) | Ambient air temperature | K |
| \(\varphi_a\) | Ambient relative humidity | - |
| \(T_{in}\) | Air temperature after heating | K |
| \(T_{out}\) | Air temperature leaving the leaf bed | K |
| \(p\) | Pressure | Pa |
| \(\dot m_w\) | Water removed | kg/s |
| \(\dot m_a\) | Dry air flow | kg/s |
| \(\dot V\) | Air volume flow at the fan (heated air) | m³/s |
| \(\varphi_{out}\) | Relative humidity of the air leaving | - |
| \(\dot Q\) | Heater duty | W |
| \(m_w/m_g\) | Withering loss as a share of green leaf | - |
Method and standards
Tea withering.
Where it is used
- Tea factory trough design and operation.
- Monsoon-season withering planning.
Common mistakes
- Using wet-basis loss as the water removed.
- Overheating the air and scorching the leaf.
Assumptions and limits
- Adiabatic trough; steady state.
References
- Psychrometrics: humidity ratio 0.621945 p_v/(p − p_v)
- humid enthalpy 1006 t + x(2 501 000 + 1860 t)
- saturation pressure from IAPWS-IF97
Questions and answers
How much water is removed in withering?
From 78 % to 68 % moisture, about 31 % of the green leaf weight.
Why heat the air only a few degrees?
A small rise sharply lowers its relative humidity and raises drying capacity without damaging the leaf.
What do the defaults represent?
An illustrative 1 t/h of green leaf withered from 78 % to 68 % with air at 22 °C and 80 % RH heated to 30 °C, leaving at 23 °C.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)