FireCADCalc

Heat Pump Dryer: SMER and Energy Saving

Specific moisture extraction rate and specific energy of a heat pump dryer from water removed and electrical input, compared with a conventional hot-air dryer.

Food, dairy and textile

Inputs

Examples: Illustrative heat pump dryerTimber dehumidifier kilnSmall herb dryer

Accepted: 0.036 to 36,000 kg/h
Accepted: 0.01 to 1,000 kW
Accepted: 0 to 1,000 kW
Accepted: 0 to 1,000 kW
Accepted: 2,000 to 2,600 kJ/kg
Accepted: 10 to 100 %

Results

A heat pump dryer condenses the water out of recirculated air on its evaporator and returns the latent heat through the condenser, so its specific moisture extraction rate (kg of water per kWh of electricity) is typically 1–4, against 0.5–1 kg per kWh of heat for a hot-air dryer. Compare costs with the price of electricity against the price of fuel heat; the energy ratio alone favours the heat pump, the price ratio may not. Low drying temperatures (below about 60 °C) suit heat-sensitive products and heat pumps alike.

Specific moisture extraction rate (kg per kWh)3.0769
Specific energy (kWh per kg)0.32500
Conventional dryer, heat per kg (kWh per kg)1.3333
Ratio of conventional heat to heat pump electricity4.1026
Dryer COP (latent heat removed per electrical energy)2.0513

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative heat pump dryer. The inputs, in the units selected above:

InputValue
Water removed40.000 kg/h
Compressor power10.000 kW
Fan power3.0000 kW
Auxiliary heater power0 kW
Latent heat of evaporation2,400.0 kJ/kg
Thermal efficiency of the conventional dryer50.000 %

Applying the formula below gives:

ResultValue
Specific moisture extraction rate (kg per kWh)3.0769
Specific energy (kWh per kg)0.32500
Conventional dryer, heat per kg (kWh per kg)1.3333
Ratio of conventional heat to heat pump electricity4.1026
Dryer COP (latent heat removed per electrical energy)2.0513

Open this example in the calculator and change any input.

Formula

\(SMER = \frac{\dot m_w}{P_c + P_f + P_h}, \quad SEC_c = \frac{\lambda}{\eta_c}\)

Variables

Symbol Meaning SI unit
\(\dot m_w\) Water removed kg/s
\(P_c\) Compressor power W
\(P_f\) Fan power W
\(P_h\) Auxiliary heater power W
\(\lambda\) Latent heat of evaporation J/kg
\(\eta_c\) Thermal efficiency of the conventional dryer -
\(SMER\) Specific moisture extraction rate (kg per kWh) -
\(SEC\) Specific energy (kWh per kg) -
\(SEC_c\) Conventional dryer, heat per kg (kWh per kg) -
\(SEC_c/SEC\) Ratio of conventional heat to heat pump electricity -
\(COP_{dryer}\) Dryer COP (latent heat removed per electrical energy) -

Method and standards

SMER.

Where it is used

  • Food, herb, timber and sludge drying.
  • Comparing dryer technologies.

Common mistakes

  • Comparing electricity and fuel kWh as if equal in price.
  • Omitting fan power.

Assumptions and limits

  • Steady operation; latent heat constant.

References

  • Specific moisture extraction rate of heat pump dryers

Questions and answers

What SMER is good?

Above about 2 kg/kWh; well-designed units reach 3–4.

Is a heat pump dryer always cheaper to run?

Only if electricity per kWh costs less than its energy advantage times the fuel heat price.

What do the defaults represent?

An illustrative heat pump dryer removing 40 kg/h with a 10 kW compressor and 3 kW fans, against a 50 % efficient hot-air dryer.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.