Worked example
Example: Illustrative 300 um particles. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Particle diameter | 300.00 µm |
| Particle density | 1,300.0 kg/m³ |
| Gas density | 0.75000 kg/m³ |
| Gas viscosity | 2.4000e-05 Pa·s |
| Gas velocity in the duct | 20.000 m/s |
| Duct length | 25.000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Terminal velocity | 1.4093 m/s |
| Particle Reynolds number at terminal velocity | 13.212 |
| Particle velocity (gas minus terminal velocity) | 18.591 m/s |
| Residence time in the duct | 1.3448 s |
Open this example in the calculator and change any input.
Formula
\(u_t = \sqrt{\frac{4(\rho_p - \rho_g)g d_p}{3C_D\rho_g}}, \quad C_D = \frac{24}{Re}\left(1 + 0.15Re^{0.687}\right), \quad \tau = \frac{L}{u_g - u_t}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d_p\) | Particle diameter | m |
| \(\rho_p\) | Particle density | kg/m³ |
| \(\rho_g\) | Gas density | kg/m³ |
| \(\mu_g\) | Gas viscosity | Pa·s |
| \(u_g\) | Gas velocity in the duct | m/s |
| \(L\) | Duct length | m |
| \(u_t\) | Terminal velocity | m/s |
| \(Re_t\) | Particle Reynolds number at terminal velocity | - |
| \(u_p\) | Particle velocity (gas minus terminal velocity) | m/s |
| \(\tau\) | Residence time in the duct | s |
Method and standards
Flash dryer.
Where it is used
- Starch, gypsum, sawdust, polymers and filter cakes.
- Choosing duct length and gas velocity.
Common mistakes
- Ignoring the acceleration zone.
- Using Stokes' law at high Reynolds number.
Assumptions and limits
- Spherical particles; steady upward flow; no wall effects.
References
- Particle slip in vertical pneumatic transport with Schiller–Naumann drag
Questions and answers
How long are particles in a flash dryer?
Usually 1–5 s; the defaults give about 1.3 s in a 25 m duct.
Why not just slow the gas down?
Below a minimum velocity the particles stop being carried and the duct chokes.
What do the defaults represent?
Illustrative 300 µm particles of density 1,300 kg/m³ in hot gas at 20 m/s up a 25 m duct.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)